INSTALLATION & OPERATING INSTRUCTIONS
1595CFKV2 CIRCULATING FAN KIT
Use with Valor models 1500K, 1700K and 1800K Linear Fireplaces
WARNING
If these instructions are not followed
exactly, a fire or explosion may result
causing property damage, personal
injury or loss of life.
GROUNDING: The power supply for this accessory must be installed and grounded in
accordance with local codes, or in the absence of local codes, with the current Canadian
Electrical Code CSA C22.1. or in the USA the National Electrical Code ANSI/NFPA70 latest
edition.
Description of System
The models 1500, 1700 and 1800 fireplaces have been
designed to accommodate the installation of an optional
150CFM air circulation fan. The fan is designed to boost
the natural convection through the heater; this may be
a desirable feature dependent on the fireplace location
and room layout.
It is preferable to install the circulating fan before
completing the heater installation although it may
also be retrofitted at a later date provided the power re-
ceptacle has been prewired within the fireplace casing.
Retrofitting the fan after the fireplace installation is com-
pleted will require disconnecting the gas and removing
the burner module and gas train from the fireplace.
The fan is designed for automatic operation to come ON
and OFF when the burner comes ON and turns OFF. The
fan speed can be controlled from the remote control
handset. There are four speeds available.
The fan, if turned ON, will start approximately 4 minutes
after lighting the appliance and will continue to run for
approximately 10 minutes after the burner is shut off.
The fan will operate at the speed last selected by the
user.
Future servicing or replacement of the fan may be done
through the window aperture of the fireplace without
needing to remove the fireplace from the wall cavity.
4007879-02
© 2021, Miles Industries Ltd. All rights reserved.
Linear
Note: This kit must be installed or serviced
by a qualified installer, service agency
or gas supplier. These instructions are
to be used in conjunction with the main
installation instructions for the above
listed models.
NOTICE
A control module GV60VM—V-Module kit
(sold separately) is required to provide
power and speed control to the fan. The
V-Module plugs into a receptacle located
within the fireplace. Ensure power is
provided to the receptacle. See Electrical
Wiring section in fireplace installation
manual for details.
Electrical Requirements
This optional fan kit connects to a control module (sold
separately) to be mounted within the fireplace casing.
The fan electrical requirements are 120 Volts, 1 phase,
60 Hz. Full load current of less than 1 amp.
Please leave this manual with the homeowner.
1