Battery chargers model HFK are designed for single phase 230V for batteries from 12 to 96V with current from 25 to
85Amps, while HFT chargers for three phase 400V for batteries from 24 up to 96V with current from 25 to 120Amps.
Putting together 2 chargers we can reach up to180A. Working frequency can be either 50 or 60Hz.
There are many kind of charging curve for Pb, Gel and AGM battery (WUIU, IUIa, IU0U and so on).
Each curve profile is set with the default factory parameters but the software allows to change the value of these
parameters by entering into a specific mode.
Software release currently available is 5.10 F.
Power-on, end of the charge and power-off
POWER-ON : Charger turns on connecting AC Main. Connecting the battery the charger starts automatically the cycle.
END OF CHARGE : When the Display shows
If a floating charge is set the display shows a letter after End: (ex:
POWER-OFF and BATTERY DISCONNECTION:
Charger switches off pressing F button for 2 times (call and confirmation) or unplugging AC Main.
Battery must be disconnected after the operation described above in order to avoid electric arcs.
Charger requires normally about 10-20 sec before shutting off completely.
WARNING: before connecting another battery wait for an acoustic sound (2 sec.) and wait for the display shows
After stopping, a charge cannot be restored. Battery must be disconnected. The charge starts from the beginning.
Display and LED information
Scrolling parameters using << and >> buttons the display shows many useful technical information such as voltage,
current, battery capacity, number of performed cycles etc. At start up, the display shows MAIN parameter (called
navigator), able to provide general information on charger status (for example charger stage or reason of a stop).
The following are just a piece of information. For having the complete number please ask for the technical manual.
(*) navigator – the display shows one of the following information depending on what is the charger doing
Charger is idle
bat
Battery is missing
Stop
Idle
End
Charge is completed
WARNING: Sequence and number of phases depends on cycle setting
LED 1 – Yellow
Flashing
Transitional Phase
Fixed
Phase 1 constant current (I=K)
Scrolling parameters on standard mode (set0) with << and >> buttons allows to know all charging information and setting
Info
During the charge
( * )
Navigator
U
Battery voltage
A
Battery current
C
Capacity accumulated
c
Capacity accumulated: phase 1+2
T
Charging time elapsed
(*) the parameter "navigator" change continuously providing general charger information.
For verifying that the charger setting is compatible with the battery you are charging and the charger is set in the right way,
please scrolls the parameters described above (Charger set up) pressing the << (P2 button).
ATIB ELETTRONICA S.R.L 25030 B
STD HFK and HFT rev 5.10F

Basic Information

A desulphation curve is provided for the nominal battery.
End
Charger is working
F xx
Standard curve
Phase 3 constant current (I=K)
Phase 2 constant voltage (V=K)
n
N
E
-
GR06_UK_Getting Started STD HFK HFT 5_10F 26mar14.docx
ARBARIGA

Getting Started

and green LED is ON the charge is over.
End5
pulse floating)
t' _
cur
time
LED 2 – Yellow
Other info
Completed charges
Partial charges
Error code
Countdown
(BS) Tel. +39 030 99 71 051 tecnico@atibelettronica.it
Page 1 of 2
26 mar 2014
Charger Error (some examples)
Overtemperature
Under current
Max time exceeded
LED 3 – Green
LED 4 – Red
Floating
Error
Battery charged
Error
Charger Set Up
0
Battery Ah
1
Battery Voltage
2
Charging Current
3
Charging profile (curve)
h
Safety timer (h)
r
Software release