Page 1
SOLO6 - TWIN6 - SUB12 Manuel d’utilisation / User Manual / Gebrauchsanleitung / Manuale d’uso / Manual de uso / Manual de utilização / Handleiding / Instrukcja obsługi / Руководство по 사용 설명서 эксплуатации / 使 用 手 册 دليل المستخدم 取扱説明書...
Page 2
Français À LIRE EN PREMIER ! INSTRUCTIONS DE SÉCURITÉ IMPORTANTES ! L'éclair représenté par le symbole fl èche et ATTENTION : Le point d’exclamation contenu dans un contenu dans un triangle équilatéral, a pour Afi n de prévenir tout risque de choc triangle équilatéral, a pour objet de prévenir objet de prévenir l’utilisateur de la présence électrique, n’enlevez pas le capot (ou...
Système de Mo nitor in g P rofession nel A n alogi que - Manuel d 'util is ati on 1 COLOR PRINTING: Line thickness (frame only): PANTONE P877C 0.40mm(+/-0.05) ENEL1261 - ELECTRONIQUE COMPLETE ST6 SOLO6 - SRDOS-201103/2 1. Connecteur d'entrée du signal audio 2. Commutateur de mise en veille automatique TWIN 6 SUB 6 3.
VUE DE FACE SOLO6 - TWIN6 - SUB12 TWIN 6 SOLO 6 SUB 6 Système de Mo nitor in g P rofession nel A n alogi que - Manuel d 'util is ati on Position A Position B Gauche/Droite Gauche/Droite Position C Position C Gauche...
Page 5
LED POWER : - marche (vert continu) - arrêt (rouge continu) - protection (rouge intermittent) 14. LED 2.1 BYPASS/mute : marche (vert continu) 1 COLOR PRINTING: Line thickness (frame only): PANTONE P877C 0.40mm(+/-0.05) ENEL1264 - ELECTRONIQUE COMPLETE ST6 SUB6 - SRDOS-201127/2...
Page 6
SOLO6 - TWIN6 - SUB12 Système de Mo nitor in g P rofession nel A n alogi que - Manuel d 'util is ati on LF / HF Shelving LF Shelving 250Hz HF Shelving 4.5kHz ±3dB / 1dB step ±3dB / 1dB step 1000 10000 100000...
Page 7
En cas de problème, adressez-vous à votre revendeur Focal. La garantie pour la France sur tout matériel Focal est de 2 ans, non transmissible en cas de revente, à partir de la date d’achat. En cas de matériel défectueux, celui-ci doit être expédié à vos frais, dans son emballage d’origine auprès du revendeur, lequel analysera le matériel et déterminera la nature de la panne.
Page 8
Focal de 6,5 pouces (16,5 cm) à membrane sandwich composite "W" chargés par un double évent laminaire de grande section et d’un tweeter Focal à dôme inversé en Béryllium pur. Les deux haut- parleurs de 6,5 pouces reproduisent le grave mais seul l’un d’entre eux (dont on peut choisir le positionnement) reproduit les fréquences "médium"...
Page 9
Mise en veille automatique Les moniteurs de la ligne ST6 sont équipés d’un mode "Veille". Quand vous mettez en marche les moniteurs, le mode "Veille" est actif. Pour le désactiver, envoyez un signal audio au moniteur en montant progressivement le niveau sonore de la source audio.
à un support ou une installation donnée, la mise en œuvre de l’installation des moniteurs relevant du seul client. Focal ne saurait donc être tenue responsable à quelque titre que ce soit en cas de décrochage, chute, accident et/ou tout autre conséquence ou dommage de quelque nature qui soit lié...
Page 11
Indicateur Un témoin "Marche/Arrêt" sous forme de "LED" se situe sur la façade avant le l’enceinte, au-dessus du témoin du mode Focus, à proximité du Logo "Focal". Mode Focus Le mode FOCUS permet de passer du mode 2 voies (et 2,5 voies pour Twin6) au mode 1 voie.
Page 12
SOLO6 - TWIN6 - SUB12 Système de Mo nitor in g P rofession nel A n alogi que - Manuel d 'util is ati on Polarité Ce commutateur de polarité inverse la phase du Sub12 de 180°. Phase Ce potentiomètre de "réglage fin" de la phase, associé au commutateur de polarité (vu ci-dessus) permettra d’éventuellement compenser le positionnement du Sub12 par rapport à...
Page 13
SOLO6 - TWIN6 - SUB12 Système de Mo nitor in g P rofession nel A n alogi que - Manuel d 'util is ati on Performances SOLO6 TWIN6 • Réponse en fréquence (@ -3 dB) 40 Hz – 40 kHz •...
Page 14
SOLO6 - TWIN6 - SUB12 Système de Mo nitor in g P rofession nel A n alogi que - Manuel d 'util is ati on Performances SUB12 • Réponse en fréquence (@ -3 dB) 28 Hz – 400 Hz • Niveau SPL max 124,5 dB (CEA2010B moyenne 30-200 Hz free field @ 1 m) Section électronique...
Page 15
English READ FIRST! IMPORTANT SAFETY INSTRUCTIONS! The bolt of lightning in an equilateral triangle WARNING: An exclamation mark in an equilateral triangle warns the user that the device has high To prevent any risk of electric shock, do not warns the user that the manual contains voltage that could result in a risk of electric remove the cover (or the back) from the important instructions on how to use and look...
Pro fe ssi o na l A na logue M onitor ing System - User Manu al 1 COLOR PRINTING: Line thickness (frame only): PANTONE P877C 0.40mm(+/-0.05) ENEL1261 - ELECTRONIQUE COMPLETE ST6 SOLO6 - SRDOS-201103/2 1. Audio signal input connector 2. Automatic stand-by switch TWIN 6 3. Input sensitivity switch SUB 6 4.
Page 17
VUE DE FACE SOLO6 - TWIN6 - SUB12 TWIN 6 SOLO 6 SUB 6 Pro fe ssi o na l A na logue M onitor ing System - User Manu al Position A Position B Left/Right Left/Right Position C Position C Left Right VUE DE FACE...
Page 18
13. On/off mode indicator POWER LED: - on (continuous green) - stop (continuous red) - protection (flashing red) 14. 2.1 BYPASS/mute LED: on (continuous green) 1 COLOR PRINTING: Line thickness (frame only): PANTONE P877C 0.40mm(+/-0.05) ENEL1264 - ELECTRONIQUE COMPLETE ST6 SUB6 - SRDOS-201127/2...
Page 19
SOLO6 - TWIN6 - SUB12 Pro fe ssi o na l A na logue M onitor ing System - User Manu al LF / HF Shelving LF Shelving 250Hz HF Shelving 4.5kHz ±3dB / 1dB step ±3dB / 1dB step 1000 10000 100000...
Page 20
Conditions of warranty All Focal loudspeakers are covered by warranty drawn up by the official Focal distributor in your country. Your distributor can provide all details concerning the conditions of warranty. Warranty cover extends at least to that granted by the legal warranty in force in the country where the original purchase invoice was issued.
Page 21
“midrange” frequencies (fig. B). Sub12 Sub12 is an active subwoofer (1 internal amplifier) for professional monitoring systems. The transducer used is a Focal 13" (33cm) subwoofer with ‘W’ composite sandwich cone, fitted with a large-section laminar port (fig. F).
Page 22
Automatic stand-by The monitors in the ST6 range are equipped with a “Stand-by” mode. When you switch on the monitors, the “Stand- by” mode is enabled. To disable it, send an audio signal to the monitor by gradually increasing the volume of the audio source.
Page 23
Focal does not provide any end-of-use warranty for a given bracket or installation, as installing the monitors is the customer's sole responsibility. Focal is therefore not liable in any capacity whatsoever in the event of unhooking, fall, accident and/or any other result or damage of any kind related to the installation of monitors.
Page 24
Light There is an On/Off “LED” indicator on the front panel of the loudspeaker, above the Focus mode indicator, near to the “Focal” logo. Focus mode FOCUS mode is used to switch from 2-way (and 2.5-way for Twin6) to 1-way mode.
Page 25
SOLO6 - TWIN6 - SUB12 Pro fe ssi o na l A na logue M onitor ing System - User Manu al Polarité This polarity switch inverts the Sub12 phase by 180°. Phase This “fine tuning” phase-adjustment potentiometer, combined with the polarity switch (seen above), will allow you to compensate for the positioning of the Sub12 in relation to that of the other loudspeakers.
Page 26
SOLO6 - TWIN6 - SUB12 Pro fe ssi o na l A na logue M onitor ing System - User Manu al Performance SOLO6 TWIN6 • Frequency response (@ -3dB) 40Hz – 40kHz • Focus mode 110Hz - 10kHz • Maximum SPL 110dB 112dB (Average CEA2034 50–10kHz free field @ 1m)
Page 27
SOLO6 - TWIN6 - SUB12 Pro fe ssi o na l A na logue M onitor ing System - User Manu al Performance SUB12 • Frequency response (@ -3dB) 28Hz – 400Hz • Maximum SPL 124.5dB (Average CEA2010B 30-200 Hz free field @ 1m) Electronic section •...
Page 40
SOLO6 - TWIN6 - SUB12 類 比 式 專 業 監 聽 系 統 - 使 用 說 明 書 類 比 式 專 業 監 聽 系 統 型號(型式): SOLO6, TWIN6, SUB12 設備名稱: Equipment name Type designation (Type) 限用物質及其化學符號 Restricted substances and its chemical symbols 單元Unit 六價鉻...
Page 41
한국어 먼저 읽을 것! 중요 안전 지침! 화살표 기호로 표시되며 정삼각형 안에 있는 주의사항: 정삼각형 안에 들어 있는 느낌표는 사용설명서에 번개 모양은 장치 내에 감전을 유발할 수 있는 감전을 방지하기 위해 본 장치의 덮개(또는 후면)을 언급되고 장치의 실행 및 유지보수와 관련된 중요 높은...
Page 42
아날로그 전문가용 모니터링 시스템 - 사용 설명서 1 COLOR PRINTING: Line thickness (frame only): PANTONE P877C 0.40mm(+/-0.05) ENEL1261 - ELECTRONIQUE COMPLETE ST6 SOLO6 - SRDOS-201103/2 1. 오디오 신호 입력 커넥터 2. 자동 대기 모드 스위치 TWIN 6 3. 입력 감도 스위치...
Page 43
VUE DE FACE SOLO6 - TWIN6 - SUB12 아날로그 전문가용 모니터링 시스템 - 사용 설명서 TWIN 6 SOLO 6 SUB 6 위치 A 위치 B 좌 / 우 좌 / 우 위치 C 위치 C 좌측 우측 VUE DE FACE TWIN 6 SUB 6 위치...
Page 44
12. 고역 통과 필터의 스위치 13.켜짐/꺼짐 모드 표시등 LED POWER: - 켜짐(녹색 지속) - 정지(빨간색 지속) - 보호(빨간색 깜빡임) 14. LED 2.1 BYPASS/mute : 켜짐(녹색 지속) 1 COLOR PRINTING: Line thickness (frame only): PANTONE P877C 0.40mm(+/-0.05) ENEL1264 - ELECTRONIQUE COMPLETE ST6 SUB6 - SRDOS-201127/2...
Page 46
Focal 제품을 구입해주셔서 감사합니다. Focal 모니터링 스피커의 세계에 오신 것을 환영합니다. 혁신과 전통, 탁월한 품질과 즐거움을 핵심 가치로 삼고 있는 Focal은 투명하고, 충실하며, 정밀한 사운드를 제공하기 위해 최선을 다하고 있습니다. 제품의 모든 성능을 활용할 수 있도록 본 책자의 지침을 읽고 나중에 참고할 수 있도록 잘 보관해 두실 것을 권장합니다.
Page 47
Twin6 스피커 시스템은 전문가용 액티브 2.5채널 (3개의 내부 앰프) 프록시미티 컨트롤 스피커 시스템으로, 큰 섹션에 이중 래미너 포트에 의해 충전되는 "W" 복합재 샌드위치 멤브레인이 장착된 6.5"(16.5 cm) 라우드스피커 두 개와 순베릴륨 역돔 Focal 트위터 하나로 구성되어 있습니다. 6.5 라우드스피커 두 개는 저음을 재생하지만 둘 중 하나(배치를 선택할 수 있음)만이 중간 주파수를...
Page 48
고정, 설치 작업은 자격이 있고 설치 및 안전 규격을 숙지하고 있는 전문가가 실시해야 합니다. Focal은 지지물 또는 특정 설비, 고객이 직접 실시한 모니터 설치 작업과 관련된 보증을 하지 않습니다. Focal은 장치 벗겨 짐, 낙하, 사고 및 모니터 설치와 관련하여 발생하는 모든 성격의 결과 또는 손상에 대해 책임을 지지 않습니다.
Page 49
모서리에 스피커를 배치할 때 매우 유용하며, 이러한 주파수를 적절히 감소시키기 좋습니다. 표시기 LED 형태의 '꺼짐/켜짐' 표시등은 스피커 앞 정면, Focus 모드 표시기 위, Focal 로고 근처에 배치되어 있습니다. Focus 모드 FOCUS 모드로 2채널 모드(Twin6의 경우 2.5 채널)를 1채널로 전환할 수 있습니다.
Page 50
SOLO6 - TWIN6 - SUB12 아날로그 전문가용 모니터링 시스템 - 사용 설명서 성능 SOLO6 TWIN6 •주파수 응답(@ -3 dB) 40 Hz – 40 kHz •Focus 모드 110 Hz - 10 kHz •최대 SPL 레벨 110 dB 112 dB (CEA2034 평균 50~10 kHz free field @ 1 m) •Focus 모드...
Page 51
SOLO6 - TWIN6 - SUB12 아날로그 전문가용 모니터링 시스템 - 사용 설명서 성능 SUB12 •주파수 응답 (@ -3 dB) 28 Hz – 400 Hz •최대 SPL 레벨 124.5 dB (CEA2010B 평균 30~200 Hz free field @ 1 m) 전자부 •입력 Balanced XLR LFE 10 kΩ, Left &...
Page 52
SOLO6 - TWIN6 - SUB12 SOLO6 - TWIN6 - SUB12 La présence du logo CE indique que le produit respecte l'ensemble des directives européennes en vigueur et applicables au produit au moment de sa mise sur le marché. La présence du logo UKCA indique que le produit respecte l'ensemble de la législation britannique en vigueur et applicable au produit au moment de sa mise sur le marché.
Page 53
Élimination correcte de ce produit. Ce marquage indique que ce produit ne doit pas être éliminé avec les autres déchets ménagers au sein de l’UE. Par mesure de prévention pour l'environnement et pour la santé humaine, veuillez le recycler de manière responsable, pour favoriser la réutilisation des ressources matérielles.
Page 54
Korrekt avlägsnande av produkten. Denna märkning anger att produkten inte ska kasseras med annat hushållsavfall inom EU. För att förhindra skada på miljö och människors hälsa, vänligen återvinn produkten ansvarsfullt för att främja återanvändning av materialresurserna. Använd tillgängliga återlämnings- och insamligssystem för att återlämna din använda anordning, eller kontakta återförsäljaren som du köpte produkten av.
Page 55
FOCAL JMLab - BP 374 - 108, rue de l'Avenir - 42353 La Talaudière cedex - France - www.focal.com ® Tel. (+33) 04 77 43 57 00 - Fax (+33) 04 77 43 57 04 - SCTL - 23/08/2022 - v2...