We recommend installing the bathtubs to already finished
walls and flooring (already tiled or laid).
Built-in models
m
WARNING: for built-in models, inspection panels
should be installed on all sides (ref. 6).
Access can be closed off using removable panels. The system
must also be equipped with adequate ventilation, with holes
between the tub coating and the removable panels, or there
should be evenly spaced and fully unobstructed openings.
The panels must be securely attached and a suitable tool
must be used for their relative removal.
Openings, holes and grilles used for ventilation purposes must
not permit the infiltration of objects with diameter of Ø 12 mm.
Freestanding models
m
WARNING: for freestanding models Arga®175x85, a
space needs to be left free for the tub during installa-
tion and for any future maintenance or repair work.
2
3
Tub fixing system with brackets (S)
(Arga®175x85 freestanding models)
These models are equipped with brackets ("S", see data sheet)
which stop the tub from moving in the event of accidental
knocks or pressure.
In the event of maintenance work which requires the tub to
be moved, first move the tub in one direction or the other, de-
pending on how the brackets have been fixed. When preparing
the floor drain, please bear this in mind and position the pipe in
one of the two areas shown (1 or 1a).
m
Drain preparations and water connections
Please prepare the floor drain in the areas indicated (see the
technical data sheet, ref. 1/1a); for Arga®175x85 freestanding
models, please see the section "Tub fixing system with brackets
(S)".
Water can be supplied via an external tap unit:
- for built-in models, position the outlet for the two pipes for hot
and cold water on the floor, as shown in ref. 5.
- for freestanding installation, if you want to place a freestand-
ing bath mixer floor mounted, during the assembly please be
sure the bathtub could be easily removed (mod. Arga® 175x85)
or at least panels could be removed (mod. Arga® 180x90): this
precaution is important to facilitate maintenance and/or the
replacement of damaged pieces.
4
(4x)
1
m
6
When fixing the brackets to the floor, make sure you do
not drill through any pipes or wires.
2
3
1
Where "hard" water is present, it is advisable to install
a decalcifier in the water system supplying the appli-
ance, in order to reduce and/or avoid calcareous de-
posits.
ATTENTION: (IEC 60335-1/A2) The pressure of the wa-
ter system supplying water to the appliance must not
exceed 600 k Pa (6 bar).