Batteries
Permissible batteries
Traction batteries are required for the use of this machine (no
wet battery sets, starter or device batteries). We recommend
the use of pure traction batteries. Only these batteries guaran-
tee a long service life.
Traction batteries are produced as closed and maintenance-
free (VRLA) batteries (gel and AGM, Pure Lead and lithium).
The machine must be adjusted according to each construction
type and manufacturer.
Each battery has a different service life and performance.
The machine and charger must be programmed after the bat-
teries have been inserted and when the battery type and/or
the manufacturer have been changed, as well as prior to start-
ing the machine.
Incorrect adjustment may result in early battery failure.
Safety measures to be taken when handling the batteries
• Attention! The battery poles are al-
ways energized. Therefore do not
deposit any objects on the batteries!
Attention:
Keep batteries clean and dry.
Attention:
Batteries may only be installed by service
agencies or experts approved by Di-
versey; they must be installed in compli-
ance with the connection diagram.
Installation and/or connection errors may
result in severe injury, explosion and major
damage to the machine and the environ-
ment.
Attention:
The operating instructions provided by the
battery manufacturer must also be ob-
served.
Attention:
Always disconnect the batteries from the
machine before starting maintenance
work.
Battery connection diagram
Power Board
12 V
12 V
Charging process
Each battery type and/or battery manufacturer requires differ-
ent charging characteristics.
Attention:
Incorrect charging characteristics or the
use of inappropriate chargers results in
early failure or the quick destruction of bat-
teries.
Optionally available on-board chargers are adapted to the bat-
tery size and contain several charging characteristics which
are adjusted ex works or by a TASKI service technician for
recommended batteries. This regulation shall also apply for
the use of stationary (external) chargers.
Attention:
Persistent short-term use with subsequent
battery charging may cause long-term
damage to the batteries. Standard value:
At least approx. 20% of the available ca-
pacity should be used up before recharg-
ing the battery.
Attention:
In order to achieve their max. possible ser-
vice life, traction batteries must undergo
the complete charging cycle (12-16 hours)
twice a week.
Attention:
Before decommissioning the machine for
a longer period, the batteries must under-
go a complete charging cycle. After com-
pletion, the charger is disconnected from
the machine and/or mains. Batteries grad-
ually discharge. Depending on the type of
battery, they must be recharged after 3-6
months. Before recommissioning, the bat-
teries should undergo another complete
charging cycle.
Battery
plug
50A
EN