Dimensions; Ul-Data; Standard Type; Ordering Example - DOLD SAFEMASTER BH 5902/01MF2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data
General Data
Operating mode:
Temperature range
Operation:
Storage:
Altitude:
Clearance and creepage
distances
Rated impulse voltage /
pollution degree:
EMC
Electrostatic discharge:
HF irradiation:
80 MHz ... 2.7 GHz:
Fast transients
on wires for power supply A1-A2: 2 kV
on wires for signals and control: 2 kV
Surge voltages
between
wires for power supply:
between wire and ground:
HF wire guided:
Interference suppression:
Degree of protection:
Housing:
Terminals:
Housing:
Vibration resistance:
Shock resistance:
Acceleration:
Impulse length:
Number of shocks:
Climate resistance:
Terminal designation:
Wire fixing:
Fixing torque:
Mounting:
Weight:

Dimensions

Width x height x depth:
E. Dold & Söhne GmbH & Co. KG • D-78120 Furtwangen
dold-relays@dold.com • www.dold.com
Continuous operation
± 0 ... + 50 °C
- 25 ... + 85 °C
≤ 2000 m
4 kV / 2 (basis insulation) IEC/EN 60664-1
8 kV (air)
IEC/EN 61000-4-2
(according to test degree 3)
10 V / m
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-4
1 kV
IEC/EN 61000-4-5
2 kV
IEC/EN 61000-4-5
10 V
IEC/EN 61000-4-6
Limit value class A*
)
*) The device is designed for the usage
under industrial conditions (Class A,
EN 55011). When connected to a low
voltage public system (Class B,
EN 55011) radio interference can be
generated.
To avoid this, appropriate measures
have to be taken.
According to IEC/EN 61496-1
the unit has to be installed in a housing
with protection degree 54.
IP 40
IEC/EN 60529
IP 20
IEC/EN 60529
Thermoplastic with V0 behaviour
according to UL subject 94
According to IEC/EN 61496-1
Amplitude 0.35 mm
IEC/EN 60068-2-6
frequency 10 ... 55 Hz
10 g
16 ms
1000 per axis on 3 axis
0 / 050 / 04
IEC/EN 60068-1
EN 50005
Terminal screws M 3.5
Box terminal with wire protection
0.8 Nm
DIN rail
IEC/EN 60 715
320 g
45 x 84 x 121 mm

UL-Data

The safety functions were not evaluated by UL. Listing is accom-
plished according to requirements of Standard UL 508, "general use
applications"
Nominal voltage U
Ambient temperature:
Switching capacity:
Ambient temperature 50°C:
Semiconductor outputs:
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo

Standard Type

BH 5902.03/01MF2/61 DC 24 V
EN 55011
Article number:
• Output:
• All functions settable via rotational switches
• Nominal voltage U
• Width:

Ordering Example

BH 5902 ._ _ /01MF2/61 DC 24 V

Characteristic

250
200
150
100
50
0
1
2
Switching current I
Safe breaking, no continuous arcing
under the curve, max. 1 switching cycle/s
Arc limit curve
Bregstraße 18 • Phone +49 7723 654-0 • Fax +49 7723 654356
36
:
DC 24 V
N
0 ... + 50 °C
Pilot duty B300
5A 250Vac G.P.
5A 24Vdc
24Vdc, 100 mA
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
0053847
3 NO contacts
:
DC 24 V
N
45 mm
Nominal voltage
Contacts
.03: 3 NO contacts
.22: 2 NO, 1 NC contacts
Type
3
4
5
6
7
8
[A]
BH 5902/01MF2 / 26.01.21 en / 296A

Publicité

Table des Matières
loading

Table des Matières