Troubleshooting - Jet JWDS-2244-M Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13.0  Troubleshooting JWDS‐2244‐M / JWDS‐2550‐M Drum Sander 
Symptom 
Drum motor won't start 
when switch is activated. 
Drum motor will not start: 
fuses blow or circuit 
breakers trip. 
Drum motor overheats. 
Drum motor stalls, 
resulting in blown fuses or 
tripped circuit. 
Loud, repetitive noise or 
vibration coming from 
machine. 
Conveyor motor stalls. 
Conveyor belt does not 
move. 
Conveyor rollers run 
intermittently. 
Conveyor belt slips on drive 
roller. 
Abrasive strip comes off 
drum. 
Abrasive strip is loose. 
Abrasive loads up 
prematurely. 
Line or groove in stock. 
All manuals and user guides at all-guides.com
Possible Cause 
No incoming current. 
 
Low voltage. 
Open circuit in motor or loose connection. Inspect all lead connections on motor for loose 
Switch malfunction. 
Short circuit in line cord or plug. 
Short circuit in motor or loose 
connections. 
Incorrect fuse or circuit breaker in power 
line. 
Air circulation through motor restricted. 
Motor overloaded (SandSmart not 
functioning properly). 
Short circuit in motor or loose 
connections. 
Low voltage. 
Incorrect fuse or circuit breaker in power 
line. 
Fasteners loose. 
Motor fan is hitting cover. 
Machine not level. 
Excessive depth of cut. 
Shaft coupler is loose or unattached. 
Shaft coupling is loose. 
Improper conveyor belt tension. 
Excessive depth of cut and/or feed rate. 
Slack in abrasive strip on drum. 
Abrasive improperly wrapped. 
Strip caught on inside edge of slot, or on 
inboard side of drum. 
Strip not cut properly. 
Excessive depth of cut. 
Excessive feed rate. 
Inadequate dust collection. 
Inadequate abrasive. 
Inconsistent feed rate. 
Correction * 
Check connections at plug or circuit panel. 
 
Check power line for proper voltage. 
or open connections. 
Replace switch. 
Inspect cord or plug for damaged insulation and 
shorted wires. 
Inspect all connections on motor for loose or 
shorted terminals or worn insulation. 
Install correct fuse or circuit breaker. 
Clean motor fan with compressed air to restore 
normal air circulation. 
Have controls inspected and repaired. 
Inspect connections on motor for loose or 
shorted terminals or worn insulation. 
Correct low voltage conditions. 
Install correct fuse or circuit breaker. 
Inspect fasteners and tighten where needed. 
Tighten fan or shim fan cover. 
Place sander on level floor; shim if needed. 
Reduce depth of cut; use coarser grit; reduce 
feed rate. 
Adjust shaft coupler. 
Align the shaft flats of the gear motor and the 
drive roller and tighten the shaft‐coupling 
setscrews. 
Adjust belt tension. 
Reduce depth of cut and/or feed rate. 
Remove slack in strip. 
Read the section on installing abrasives, and 
rewrap. 
Re‐adjust the strip end in the slot and/or trim 
the abrasive edge. 
Re‐cut and re‐install the abrasive strip. 
Reduce depth of cut. 
Reduce feed rate. 
Increase airflow at dust port. 
Use an open‐coat abrasive. 
Do not stop or change the feed rate while 
feeding stock. 
20

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jwds-2550-m

Table des Matières