Télécharger Imprimer la page

Jydepejsen EOS Mode D'emploi page 27

Masquer les pouces Voir aussi pour EOS:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. Maintenance
Sealing strips and Vermiculite panels are wearing parts which need to be replaced from time to time – de-
pending on how much you use your stove. In some cases, you may need to replace them every year, while in
others, replacement every second or third year will suffice. As a rule of thumb, the sealing strip needs to be
replaced when it has become flattened and the door no longer fits tightly against the front of the stove. You
can purchase sets of sealing strip – with adhesive – from your local dealer.
The Vermiculite panels must be replaced when they have worn thin, or when cracks – if any – become so
wide that you can actually see steel through them. If the panels are not replaced at such time, they will lose
their capacity to insulate and reflect heat.
We recommend that you use original spare parts.
Movable and mechanical parts (closing mechanisms, hinges etc) should be greased once a year with a
heat-resistant lubricant.
You should have your stove checked regularly by a qualified professional to ensure the optimal function of
the stove at all times. Do not make any unauthorised changes to the design of the stove. Not only is this
illegal, but it will also invalidate the stove guarantee and test results.
Replacing the sealing strip on the door
1. Remove the sealing strip from the inside edge of the door and clean the sealing track (there is no need
to remove the door from the stove).
2. Apply a layer of fire-resistant adhesive to the track where the old sealing strip was affixed.
3. Press new sealing strip into the track.
4. Close the door and let the adhesive set for approx. 1 day before opening the door again. If the adhesive
has not hardened sufficiently before the door is opened again, the sealing strip may fall out.
Interior cleaning
It must always be possible to access the chimney for sweeping/cleaning.
The ashes must frequently be removed from the combustion chamber. BE CAREFUL not to empty hot ashes
directly into the waste bag - there may be embers even 24 hours after the fire has gone out.
Before chimney sweeping, the baffle plates should be removed. When the plates are removed, loose soot
may fall down into the combustion chamber. Shut off the air supply and the door, to prevent soot and ashes
from coming out.
All manuals and user guides at all-guides.com

Publicité

loading