Liens rapides

WPR 2006
Wärmepumpen-
Regler
für Nieder-, Mittel-
und Hochtemperatur–
Wärmepumpen mit
WPC-Steuerung zum
Heizen und Kühlen
Bestell-Nr. / Order no. / N
All manuals and user guides at all-guides.com
Heat Pump
Controller
for low, medium
and high temperature
heat pumps with
HPC control for
heating and cooling
o
de commande : 452114.66.49
Montage- und
Inbetriebnahmeanweisung
für den Installateur
Installation and
Start-up Instructions
for Technicians
Notice de montage et
de mise en service
pour l'installateur
Régulateur de la
pompe à chaleur
pour température basse,
-modérée, -haute
Pompes à chaleur avec
commande WPC pour le
chauff age et le rafraîchisse-
ment
FD 8611

Publicité

loading

Sommaire des Matières pour Dimplex WPR 2006

  • Page 1 All manuals and user guides at all-guides.com WPR 2006 Montage- und Inbetriebnahmeanweisung für den Installateur Installation and Start-up Instructions for Technicians Notice de montage et de mise en service pour l‘installateur Wärmepumpen- Heat Pump Régulateur de la Regler Controller pompe à chaleur für Nieder-, Mittel-...
  • Page 2 All manuals and user guides at all-guides.com Einstellung der Sprache Instellen van de taal Bei Netzwiederkehr ist in der Displayanzeige die Auswahl Wanneer het net weer ter beschikking staat, kan in het der Sprache möglich. display de taal gekozen worden. Dazu die Taste ENTER (↵) betätigen und Druk hiervoor op de ENTER-toets (↵) en Gewünschte Sprache mit Pfeiltasten (⇑...
  • Page 3: Table Des Matières

    All manuals and user guides at all-guides.com Inhaltsverzeichnis Inhaltsverzeichnis 1 Wichtige Hinweise ............................D-4 2 Lieferumfang Wärmepumpenregler ......................D-4 3 Montage ................................D-4 3.1 Befestigung des wandmontierten Wärmepumpenreglers ......................D-4 3.2 Temperaturfühler (Heizungsregler N1) ............................D-5 3.2.1 Montage des Außentemperaturfühlers ..........................D-5 3.2.2 Montage des Regeltemperaturfühlers ..........................
  • Page 4: Wichtige Hinweise

    All manuals and user guides at all-guides.com 1 Wichtige Hinweise Bei der Inbetriebnahme sind die länderspezifischen sowie Zur Gewährleistung der Frostschutzfunktion darf der einschlägigen VDE-Sicherheitsbestimmungen, Wärmepumpenregler nicht spannungsfrei geschaltet und insbesondere 0100 Technischen die Wärmepumpe muss durchströmt werden. Anschlussbedingungen Die Schaltkontakte der Ausgangsrelais sind entstört. Energieversorgungsunternehmen (EVU) Deshalb wird abhängig vom Innenwiderstand eines...
  • Page 5: Temperaturfühler (Heizungsregler N1)

    All manuals and user guides at all-guides.com Montage 3.2 Temperaturfühler (Heizungsregler N1) Alle Wärmepumpenregler anzuschließenden Außentemperatur (Kap. 3.2.1 auf S. 5) Temperaturfühler entsprechen der in Abb. 3.3 auf S. 5 gezeigten Regelfühler Vor- oder Rücklauftemperatur (Mischerkreis) Fühlerkennlinie. Warmwassertemperatur Je nach Einbindungsart sind folgende Temperaturfühler Raumklimastation zur Temperatur- und Feuchtemessung zusätzlich zu montieren: Temperatur in °C...
  • Page 6: Elektrische Anschlussarbeiten Wärmepumpe

    All manuals and user guides at all-guides.com 4 Elektrische Anschlussarbeiten Wärmepumpe Die 4-adrige bzw. 3-adrige Versorgungsleitung für den Leistungsteil Wärmepumpe wird Wärmepumpenzähler über das EVU-Sperrschütz (falls gefordert) in die Wärmepumpe geführt (3L/PE~400V,50Hz) bzw. 1L/N/PE~230V,50Hz). Absicherung nach Angabe der Stromaufnahme auf dem Typschild, durch einen...
  • Page 7 All manuals and user guides at all-guides.com Elektrische Anschlussarbeiten Wärmepumpe Legende zu Abb. 4.2 auf S. 7 Schütz Flanschheizung K24 Relais Warmwasser-Anforderung Brücke EVS (J4/ID3-EVS nach X2/0V) muss eingelegt werden, wenn kein EVU-Sperrschütz vorhanden ist M21* Mischer Hauptkreis (Kontakt offen = EVU-Sperre). Wandregler Brücke SPR (J4/ID2-SPR nach X2/0V) einlegen bei N3* Raumstation...
  • Page 8: Vorkonfiguration Der Wärmepumpen-Heizungsanlage

    All manuals and user guides at all-guides.com 5 Vorkonfiguration der Wärmepumpen-Heizungsanlage Durch die Vorkonfiguration wird dem Regler mitgeteilt, welche Einstellbereiche dargestellt, Werte in Fettdruck kennzeichnen Komponenten Wärmepumpen-Heizungsanlage die Werkseinstellung. angeschlossen sind. Vorkonfiguration muss Die Werkseinstellung im Menü „Vorkonfiguration“ entspricht dem anlagenspezifischen Einstellungen erfolgen, um Menüpunkte Einbindungsschema einer monoenergetisch betriebenen 1- ein- bzw.
  • Page 9: Konfiguration Der Wärmepumpen-Heizungsanlage

    All manuals and user guides at all-guides.com Konfiguration der Wärmepumpen-Heizungsanlage 6 Konfiguration der Wärmepumpen-Heizungsanlage In der Konfigurationsebene sind neben dem erweiterten (ca. 5 Sekunden) der Tastenkombination (MENUE) und Einstellungsmenü, zusätzlich die Menüs „Ausgänge“, „Eingänge“ (ENTER ↵ und „Sonderfunktionen“ einstellbar. In die erweiterte Menüebene Auswahl des gewünschten Menüpunktes mit den Pfeiltasten und für den Installateur gelangt man durch gleichzeitiges Drücken Bestätigen mit der ENTER-Taste (...
  • Page 10: Ausgänge

    All manuals and user guides at all-guides.com Einstellbereich Anzeige Anlagenspezifische Parameter Einstellung der gewünschten 15,0°C / 001 1. Heizkreis Raumsolltemperatur und des I-Anteils bei ... 20,0°C .../ ...60 ... Raumregelung gewählter Raumtemperaturregelung 1.Heizkreis 30,0°C / 999 Einstellung des Temperaturwertes, um den die 1.
  • Page 11: Eingänge

    All manuals and user guides at all-guides.com Konfiguration der Wärmepumpen-Heizungsanlage 6.3 Eingänge Das Menü „Eingänge“ stellt je nach Anlagenkonfiguration die Statusanzeige „Kontakt offen oder geschlossen“ für folgende digitale Eingänge dar: Statusanzeige aller digitalen Eingänge Kontakt geschlossen entspricht Anforderung immer Kontakt offen entspricht Sperre immer Kontakt offen entspricht Sperre immer...
  • Page 12: Energieeffizienter Betrieb

    All manuals and user guides at all-guides.com 7 Energieeffizienter Betrieb Erfolgt der Heizbetrieb außentemperaturabhängig berechnet der Lange Laufzeiten der Wärmepumpe mit bedarfsabhängiger Heizungsregler aus der eingestellten Heizkennlinie und der Erwärmung gesamten umgewälzten aktuellen Außentemperatur eine Rücklaufsolltemperatur. Heizungsvolumens. Erfassung der Störgrößen des Heizsystems (z.B. passive Heizkurve sollte berechnete...
  • Page 13: Einstellbeispiele

    All manuals and user guides at all-guides.com Energieeffizienter Betrieb 7.1.1 Einstellbeispiele Fußbodenheizung Radiatoren 35 °C / 28 °C 55 °C / 45 °C Norm-Außenlufttemperatur °C 35 °C 35 °C 35 °C 55 °C 55 °C 55 °C Benötigte Vorlauftemperatur (bei Normauslegungstemperatur) 7 °C 7 °C 7 °C...
  • Page 14: Optimierung Der Heizkurve

    All manuals and user guides at all-guides.com 7.1.2 Optimierung der Heizkurve Es gibt zwei Einstellungsmöglichkeiten zur Optimierung der Anhebung bzw. Absenkung der gesamten Heizkurve durch Heizkurve: die Tasten Wärmer ( ) und Kälter ( ⇑ ⇓ Veränderung der Steigung durch einen höheren bzw. niedrigeren „Heizkurven Endpunkt“...
  • Page 15: Warmwasserbereitung

    All manuals and user guides at all-guides.com Warmwasserbereitung 8 Warmwasserbereitung Für die Warmwasserbereitung sind Warmwasserspeicher mit Für höhere Warmwassertemperaturen bietet ausreichend großen Tauscherflächen einzusetzen, die in der Wärmepumpenregler die Möglichkeit zur Ansteuerung einer Lage sind die maximale Heizleistung der Wärmepumpe Flanschheizung.
  • Page 16: Ansteuerung Des 2. Wärmeerzeugers

    All manuals and user guides at all-guides.com 9.3 Ansteuerung des 2. Wärmeerzeugers 9.3.1 Ansteuerung von Tauchheizkörpern monoenergetischen Anlagen werden elektrische Vorkonfigurationsmenü die Betriebsweise „Monoenergetisch“ Zusatzheizungen verwendet. Diese werden gewählt und die eingestellte Grenztemperatur (siehe Kap. 9.1 wärmebedarfsabhängig ein- bzw. ausgeschaltet, wenn im auf S.
  • Page 17: Hysterese

    All manuals and user guides at all-guides.com Wärmepumpenregler für Kühlen 10.2 9.5 Hysterese Hysterese Rücklaufsolltemperatur Menü „Einstellungen“ kann für verschiedene Anforderungen die sogenannte Hysterese eingestellt werden. Für die Heizanforderung kann eine Hysterese um die Die Hysterese bildet eine „neutrale Zone“ um die entsprechende Rücklaufsolltemperatur eingestellt werden.
  • Page 18: Sonderzubehör

    All manuals and user guides at all-guides.com 11 Sonderzubehör 11.1 Fernbedienstation Komforterweiterung Sonderzubehör eine genutzt werden (detaillierte Beschreibung siehe Anleitung Fernbedienstation erhältlich. Bedienung und Menüführung sind Fernbedienstation). Der Anschluss erfolgt über ein 6-adriges identisch denen Wärmepumpenreglers, durch Telefonkabel (Sonderzubehör) mit Westernsteckern. ergänzende Drucktasten können jedoch zusätzliche Funktionen 11.2 Raumklimastation Bei der Kühlung über Flächenheiz-/kühlsysteme erfolgt die...
  • Page 19 All manuals and user guides at all-guides.com Table of contents Table of contents 1 Important Information............................. E-2 2 Heat Pump Controller: Scope of Supply....................... E-2 3 Installation ............................... E-2 3.1 Attaching the Wall-mounted Heat Pump Controller ........................E-2 3.2 Temperature Sensor (Heating Controller N1) ..........................E-3 3.2.1 Mounting the External Temperature Sensor.........................
  • Page 20: Important Information

    All manuals and user guides at all-guides.com 1 Important Information During start-up, observe the respective national safety To ensure that the antifreeze function of the heat pump regulations and the applicable VDE safety regulations, works properly, the heat pump controller must remain particularly VDE 0100 as well as the technical connection connected to the power supply and the flow must be requirements of the utility companies and network...
  • Page 21: Temperature Sensor (Heating Controller N1)

    All manuals and user guides at all-guides.com Installation 3.2 Temperature Sensor (Heating Controller N1) All temperature sensors to be connected to the heat pump Control sensor for flow or return flow temperature (mixer controller have the sensor characteristic curve illustrated in Fig. circuit) 3.3 on p.
  • Page 22: Electrical Installations For The Heat Pump

    All manuals and user guides at all-guides.com 4 Electrical Installations for the Heat Pump The four-core or three-core supply cable for the output section of the heat pump is routed from the heat pump meter via the utility company's blocking contactor (if required) into the heat pump (3L/PE~400 V, 50 Hz) or 1L/N/ PE~230 V, 50 Hz).
  • Page 23 All manuals and user guides at all-guides.com Electrical Installations for the Heat Pump Legends for Fig. 4.2 on p. 5 Contactor for flange heater K24 Relay for hot water request The utility bridge (J4/ID3-EVS to X2/0 V) must be inserted if no utility blocking contactor is fitted M21* Mixer for main circuit (contact open = utility block).
  • Page 24: Preconfiguring The Heat Pump Heating System

    All manuals and user guides at all-guides.com 5 Preconfiguring the Heat Pump Heating System The preconfiguration informs the controller about which corresponding setting ranges. Values in bold print indicate the components are connected to the heat pump heating system. factory settings. Preconfiguration must be carried out before the system-specific The factory settings in the “Preconfiguration”...
  • Page 25: Configuring The Heat Pump Heating System

    All manuals and user guides at all-guides.com Configuring the Heat Pump Heating System 6 Configuring the Heat Pump Heating System The menus for “Outputs”, “Inputs” and “Special functions” as well simultaneously pressing the button combination (MENU) and as the extended setting menu can be set at the configuration (ENTER ) (for approx.
  • Page 26: Outputs

    All manuals and user guides at all-guides.com Setting range Display System-specific parameters Sets the desired room set temperature and I 15.0 °C / 001 Heating circuit 1 ratio when room temperature regulation is ... 20.0 °C .../ ...60 .. Heating circuit 1 selected reference room 30.0 °C / 999...
  • Page 27: Inputs

    All manuals and user guides at all-guides.com Configuring the Heat Pump Heating System 6.3 Inputs Depending on the system configuration, the “Inputs” menu shows the “Contact open or closed” status display for the following digital inputs: Status display of all digital inputs Contact closed means a request is pending Always Contact open denotes a block...
  • Page 28: Energy-Efficient Operation

    All manuals and user guides at all-guides.com 7 Energy-Efficient Operation If heating operation is carried out on the basis of the external Long runtimes for the heat pump with all of the circulated temperature, the heating controller calculates a return set heating volume heated according to need.
  • Page 29: Examples Of Settings

    All manuals and user guides at all-guides.com Energy-Efficient Operation 7.1.1 Examples of Settings Underfloor heating Radiators 35 °C / 28 °C 55 °C / 45 °C Standard external air temperature in °C 35 °C 35 °C 35 °C 55 °C 55 °C 55 °C Required flow temperature...
  • Page 30: Heating Curve Optimization

    All manuals and user guides at all-guides.com 7.1.2 Heating Curve Optimization There are two setting options for optimizing the heating curve: Raising or lowering the entire heating curve by means of the buttons Hotter ( ) and Colder ( ⇑ ⇓...
  • Page 31: Domestic Hot Water Preparation

    All manuals and user guides at all-guides.com Domestic Hot Water Preparation 8 Domestic Hot Water Preparation Hot water cylinders with a sufficient heat exchanger area should For higher hot water temperatures, the heat pump controller be used for DHW preparation. These must be capable of offers optional control of a flange heater.
  • Page 32: Control Of The 2Nd Heat Generator

    All manuals and user guides at all-guides.com 9.3 Control of the 2nd Heat Generator 9.3.1 Control of Immersion Heaters Supplementary electric heating systems are used in mono selected in the preconfiguration menu and the set limit energy systems. These are switched on or off depending on the temperature (see Chap.
  • Page 33: Hysteresis

    All manuals and user guides at all-guides.com Heat Pump Controller for Cooling 10.2 9.5 Hysteresis The so-called hysteresis for the different requests can be set in If the hysteresis is large, the heat pump will operate longer, the “Settings” menu. The hysteresis forms a “neutral zone” whereupon the temperature fluctuations in the return flow are around the corresponding set temperature.
  • Page 34: Special Accessories

    All manuals and user guides at all-guides.com 11 Special Accessories 11.1 Remote control A remote control adds convenience and is available as a special description, see remote control instructions). The remote control accessory. Operation and menu navigation are identical to that of is connected via a 6-core telephone cable (special accessory) the heat pump controller.
  • Page 35 All manuals and user guides at all-guides.com Table des matières Table des matières 1 Importantes informations..........................F-2 2 Fourniture du régulateur de pompe à chaleur ..................... F-2 3 Montage ................................F-2 3.1 Fixation du régulateur de pompe à chaleur mural..........................F-2 3.2 Sonde de température (régulateur chauffage N1) .........................F-3 3.2.1 Montage de la sonde de température extérieure........................F-3...
  • Page 36: Importantes Informations

    All manuals and user guides at all-guides.com 1 Importantes informations Lors de la mise en service, il faut respecter les dispositions Pour garantir la fonction de protection antigel de la pompe à de sécurité nationales ou européennes spécifiques, chaleur, le régulateur de pompe à chaleur ne doit pas être notamment la norme DIN VDE 0100, et les conditions hors tension et la pompe à...
  • Page 37: Sonde De Température (Régulateur Chauffage N1)

    All manuals and user guides at all-guides.com Montage 3.2 Sonde de température (régulateur chauffage N1) Toutes les sondes de température à raccorder au régulateur de Température extérieure (Chap. 3.2.1 à la page 3) chauffage des pompes à chaleur sont conformes aux Sonde de régulation de la température de départ ou de caractéristiques de sonde présentées à...
  • Page 38: Travaux De Raccordement Électrique De La Pompe À Chaleur

    All manuals and user guides at all-guides.com 4 Travaux de raccordement électrique de la pompe à chaleur La ligne d’alimentation à 3 ou 4 fils pour la partie puissance de la pompe à chaleur est amenée du compteur de la pompe à chaleur (3L/PE~400 V, 50 Hz ou 1L/N/PE~230 V, 50 Hz) par le contacteur de la société...
  • Page 39 All manuals and user guides at all-guides.com Travaux de raccordement électrique de la pompe à chaleur Légende Fig. 4.2 à la page 5 Contacteur cartouche chauffante K24 Relais demande eau chaude Pont coupure fournisseur d'énergie (J4/ID3-EVS avec X2/ 0 V) à insérer si aucun contacteur de blocage de la M21* Mélangeur circuit principal société...
  • Page 40: Pré-Configuration De L'installation De Chauffage À Pompe À Chaleur

    All manuals and user guides at all-guides.com 5 Pré-configuration de l’installation de chauffage à pompe à chaleur Les composants connectés à l’installation de chauffage à pompe de réglage correspondantes, les valeurs en gras indiquant le à chaleur sont transmis via la pré-configuration au régulateur. La réglage à...
  • Page 41: Configuration De L'installation De Chauffage Par Pompe À Chaleur

    All manuals and user guides at all-guides.com Configuration de l’installation de chauffage par pompe à chaleur 6 Configuration de l’installation de chauffage par pompe à chaleur Au niveau configuration, parallèlement au menu de réglage menus réservé aux professionnels en appuyant simultanément étendu, les menus «...
  • Page 42 All manuals and user guides at all-guides.com Plage de réglage Affichage Paramètres spécifiques à l’installation Le point final de la courbe de chauffe est à 20°C 1er circuit de régler conformément au dimensionnement de chauffage ... 30°C ... l’installation de chauffage. Il faut pour cela Régulation asservie 70°C indiquer la température de retour maximale,...
  • Page 43: Sorties

    All manuals and user guides at all-guides.com Configuration de l’installation de chauffage par pompe à chaleur 6.2 Sorties Le menu Sorties représente selon la configuration des installations l’affichage de l’état Arrêt ou Marche pour les sorties suivantes : Affichage toujours toujours toujours toujours...
  • Page 44: Mode Utilisant L'énergie De Façon Optimale

    All manuals and user guides at all-guides.com 7 Mode utilisant l’énergie de façon optimale Si le mode chauffage est asservi à la température extérieure, le De longues durées de fonctionnement avec réchauffement régulateur de chauffage calcule une température de retour de en fonction des besoins du volume complet de brassage de consigne à...
  • Page 45: Exemples De Réglage

    All manuals and user guides at all-guides.com Mode utilisant l’énergie de façon optimale 7.1.1 Exemples de réglage Chauffage par le sol Radiateurs 35 °C / 28 °C 55 °C / 45 °C Température de l’air extérieur normalisée °C 35 °C 35 °C 35 °C 55 °C...
  • Page 46: Optimisation De La Courbe De Chauffe

    All manuals and user guides at all-guides.com 7.1.2 Optimisation de la courbe de chauffe Il existe deux possibilités de réglage pour optimiser la courbe de Elévation ou abaissement de toute la courbe de chauffage à chauffe : l'aide des touches Plus chaud ( ) et Plus froid ( ⇑...
  • Page 47: Production D'eau Chaude

    All manuals and user guides at all-guides.com Production d’eau chaude 8 Production d’eau chaude Pour la production d´eau chaude, il faut utiliser des réservoirs Le régulateur de pompe à chaleur peut également commander d’eau chaude proposant des surfaces d’échangeur suffisamment une cartouche chauffante pour obtenir des températures plus grandes, capables de transmettre de façon permanente la élevées de l’eau chaude.
  • Page 48: Blocage Société Électricité / Blocage Du Fonctionnement Des Pompes À Chaleur

    All manuals and user guides at all-guides.com 9.2 Blocage société électricité / Blocage du fonctionnement des pompes à chaleur Une mise hors circuit temporaire de la pompe à chaleur venant Pour des installations sans blocage de la société d’électricité, le des sociétés distributrices d’électricité...
  • Page 49: Pompes À Chaleur Avec Deux Compresseurs

    All manuals and user guides at all-guides.com Régulateur de pompe à chaleur pour le rafraîchissement 10.1 9.4.2 Pompes à chaleur avec deux compresseurs Niveau de puissance Pompe à chaleur avec un compresseur Niveau P1 un seul compresseur synchrone Niveau P2 Niveau P3 1 compresseur et un deuxième générateur de chaleur, si nécessaire Dégivrage...
  • Page 50: Rafraîchissement "Silencieux" Et Dynamique

    All manuals and user guides at all-guides.com 10.2 10.1.3 Rafraîchissement "silencieux" et dynamique Selon le schéma d’intégration, différentes configurations de Combinaison des rafraîchissements dynamique et l’installation peuvent être réalisées : "silencieux" La régulation s’effectue séparément dans deux circuits de Rafraîchissement dynamique (ventilo-convecteurs p. ex.) régulation.
  • Page 51 All manuals and user guides at all-guides.com Anhang / Appendix / Annexes Anhang / Appendix / Annexes 1 Technische Geräteinformationen / Technical Device Information / Informations techniques sur les appareils ................................A-II 2 Hydraulische Einbindung / Hydraulic Integration / Connexion hydraulique..........A-II 2.1 Heizen mit Warmwasser-Thermostat / Heating with Hot Water Thermostat / Chauffage avec thermostat eau chaude....
  • Page 52: Technische Geräteinformationen / Technical Device Information / Informations Techniques Sur Les Appareils

    All manuals and user guides at all-guides.com 1 Technische Geräteinformationen / Technical Device Information / Informations techniques sur les appareils 230 V AC 50 Hz Netzspannung Supply voltage Tension secteur 195 bis/to/à 253 V AC Spannungsbereich Voltage range Plage de tension etwa/approx./env.
  • Page 53: Heizen Oder Dynamische Kühlung Mit Warmwasser-Fühler / Heating Or Dynamic Cooling With Hot Water Sensor / Chauffage Ou Rafraîchissement Dynamique Avec Sonde D'eau Chaude

    All manuals and user guides at all-guides.com Hydraulische Einbindung / Hydraulic Integration / Connexion hydraulique 2.2 Heizen oder dynamische Kühlung mit Warmwasser-Fühler / Heating or Dynamic Cooling with Hot Water Sensor / Chauffage ou rafraîchissement dynamique avec sonde d’eau chaude 2.3 Heizen oder stille und dynamische Kühlung ohne Warmwasser- Bereitung / Heating or Silent and Dynamic Cooling without DHW Preparation / Chauffage ou rafraîchissement dynamique et "silencieux"...
  • Page 54: Heizen Oder Stille Und Dynamische Kühlung Mit Warmwasser-Thermostat / Heating Or Silent And Dynamic Cooling With Hot Water Thermostat / Chauffage Ou Rafraîchissement Dynamique Et "Silencieux" Avec Thermostat Eau Chaude

    All manuals and user guides at all-guides.com 2.4 Heizen oder stille und dynamische Kühlung mit Warmwasser- Thermostat / Heating or Silent and Dynamic Cooling with Hot Water Thermostat / Chauffage ou rafraîchissement dynamique et "silencieux" avec thermostat eau chaude A-IV...
  • Page 55: Legende / Legend / Légende

    All manuals and user guides at all-guides.com Hydraulische Einbindung / Hydraulic Integration / Connexion hydraulique 2.5 Legende / Legend / Légende Wärmepumpe Heat pump Pompe à chaleur Wärmepumpenregler Heat pump controller Régulateur de pompe à chaleur Pufferspeicher Buffer tank Réservoir tampon Warmwasserspeicher Hot water cylinder Réservoir d’eau chaude...
  • Page 56: Stromlaufpläne / Circuit Diagrams / Schémas Électriques

    All manuals and user guides at all-guides.com 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Wärmepumpenmanager Heizen / Heat Pump Manager Heating / Gestionnaire de pompe à chaleur chauffage Abb. / Fig. / Fig. 3.1: Anschlussplan des wandmontierten Wärmepumpenmanagers WPM 2004 plus / Circuit diagram for the WPM 2004 plus wall-mounted heat pump manager / Schéma électrique du gestionnaire de pompe à...
  • Page 57: Legende Zum Stromlaufplan Wärmepumpenmanager Heizen/Kühlen / Heat Pump Manager Heating And Cooling: Circuit Diagram Legend / Légende Du Schéma Électrique Du Gestionnaire De Pompe À Chaleur Chauffage Et Rafraîchissement

    All manuals and user guides at all-guides.com Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1.1 Anschluss externer Anlagenkomponenten / Connection of External System Components / Raccordement composants externes de l'installation 3.1.1.1 Eingänge / Inputs / Entrées Anschluss / Connection / Erläuterung Explanation Significations...
  • Page 58 All manuals and user guides at all-guides.com digitale Eingänge: Digital inputs: Entrées numériques : ID1 Anforderung Warmwasser ID1 Hot water request ID1 Demande eau chaude ID2 externe Sperre ID2 External disable contact ID2 Blocage externe ID3 EVU-Sperre ID3 Utility block ID3 Blocage société...
  • Page 59 All manuals and user guides at all-guides.com Stromlaufpläne / Circuit Diagrams / Schémas électriques 4 Diagnose Störungen - Alarm / Troubleshooting - Alarm / Diagnostic écran perturbations - alarmes Erklärung / Explanation / Explication Maßnahmen / Measures / Mesures à prendre Die Wärmepumpe wurde durch Erreichen der Sieb im Schmutzfänger reinigen.
  • Page 60 All manuals and user guides at all-guides.com Garantiebedingungen Kundendienstadresse siehe Irrtümer und Änderungen vorbehalten. Montage- und Gebrauchsanweisung Wärmepumpe. Subject to alterations and errors. Sous réserve d’erreurs et modifications. For the terms of the guarantee and after-sales service addresses, please refer to the Installation and Operating Instructions for Heat Pumps.