Installation
FIRE, EXPLOSION, BURN INJURY CARBON
MONOXIDE POISONING
The cooking appliance must be completely separated
and/or sealed from other air moving or air consuming
devices such as, but not limited to furnaces, microwave
ovens clothes dryers, cooling fans and doors or drawers
in common cabinets. Failure to do so will affect the
appliance(s) combustion air supply by creating either a
negative or positive draft.
NEGATIVE DRAFT caused by air moving appliances
may draw the top burner flame down into or toward
the cooktop resulting in cooktop damage, burn hazard,
explosion possibility and/or carbon monoxide build up.
POSITIVE DRAFT may blow out the top burner flame
during use resulting in an explosion and/or fire hazard
and/or injury to the occupants of the vehicle.
DO NOT operate the appliance in excessive windy
conditions as this may cause a negative or positive
draft.
WARNING
Installation of this appliance must be made in accordance
with the written instructions provided in this manual. No
agent, representative or employee of Furrion or other
persons has the authority to change, modify or waive any
provision of the instructions contained in this manual.
The installation must conform with local codes or in the
absence of such codes, refer to the latest edition of:
In the U.S.A.:
a. Standard for Recreational Vehicles NFPA 1192
b. National Fuel Gas Code ANSI Z223.1/NFPA 54
In Canada, the installation must conform with:
a. Standard CAN/CSA Z-240.4.2-08, Installation
Requirements for Propane Appliances and Equipment in
Recreational Vehicles.
b. Any applicable local codes and regulations
What's in the Box
Make sure you have all the following items included in the
packaging. If any item is damaged or missing, contact your
dealer.
Range Oven x 1
Cooktop Grate x 2
Cooking Rack x 1
Instruction Manual x 1
Warranty Manual x 1
WARNING
Cabinet Cutout Instructions
For proper operation of your cooking appliance, the cabinets
must be properly constructed and squared with respect to
the counter top and the cabinet face.
For proper operation of these units, the cabinet must be level
and the bottom of the range must be supported.
NOTES: When planning the location, consider curtains or
other combustible materials installed around the appliance
so as not to create a fire hazard.
The minimum horizontal distance(s) from sides and back of
appliance to adjacent vertical combustible walls extending
above the top panel:
Item
A
7¼" Min. (184mm Min.)
B
8" Min. (203mm Min.)
NOTE: These distances shall be from the burner center of
the appliance.
Dimension
7