Duty Cycle - MasterCraft 052-0052-2 Manuel D'instructions

Table des Matières

Publicité

17
model no. 052-0052-2 | contact us 1-800-689-9928

DUTY CYCLE

Range
5 – 95%
Input Voltage: 4 – 10 V P-P
Frequency Range: 4 Hz – 1 kHz
CAPACITANCE
Range
40 nF
400 nF
4 μF
40 μF
400 μF
1000 μF
NOTE: Use Relative mode to subtract the residual capacitance of the
All manuals and user guides at all-guides.com
Resolution
0.1%
Resolution
10 pF
100 pF
1 nF
10 nF
100 nF
1 μF
test leads and the meter.
If the capacitance being measured is > 1000 μF, the display
may show a reading, but the measurement error may be
large. If the capacitance being measured is > 4000 μF, "OL"
will be shown on the display.
Accuracy
± ( 2.0% + 7 )
Accuracy
± (3.5% + 20)
± (2.5% + 5)
± (3.5% + 5)
± (4.0% + 5)
± (5.0% + 5)
not specified
Remark
Auto-range
Remark
Auto-range

Publicité

Table des Matières
loading

Table des Matières