TECHNICAL SPECIFICATIONS
Readings are accurate for a period of 1 year after calibration at 64 to
82ºF (18 to 28ºC), with relative humidity up to 75%.
Accuracy specifications take the form of:
± [(% of Reading) + (Number of Least Significant Digits)]
DC VOLTAGE
Range
400 mV
4 V
40 V
400 V
600 V
Input Impedance: 10 MΩ
Max. Allowable Input Voltage: 600 V DC
[1]If the voltage being measured is >600 V, the display may show
NOTE: The 600 V range is accurate from 20 to 100% of range.
All manuals and user guides at all-guides.com
Resolution
0.1 mV
1 mV
10 mV
0.1 V
1 V
the value of the voltage, but the measurement is dangerous.
Accuracy
"OL" shown on
± (0.8% + 5)
± (1.0% + 5)
Overrange
Indication
the display
See[1]