Mustek PowerMust 2000 Sinewave LCD Online IEC Guide Rapide page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
EN
UPS Setting
01: Output voltage setting
200/208/220/230(Default)/240VAC
02: Frequency Converter
enable/disable
CF ENA: converter mode enable
CF DIS: converter mode
disable(Default)
03: Output frequency setting
You may set the initial frequency on
battery mode (BAT) or Converter
Mode (CF) is enabled.
BAT 50/ BAT 60/CF 50/ CF 60
04: ECO enable/disable
ENA/ DIS (Default)
MODEL
CAPACITY*
Voltage
Range
INPUT
Frequency Range
Output voltage
AC Voltage Regulation
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Current Crest Ratio
OUTPUT
Harmonic Distortion
Transfer
Time
Waveform (Batt. Mode)
Recharge Time
Tower
BATTERY
Rack/Tower
Tower
PHYSICAL
Tower/Rack
Operation Humidity
ENVIRONMENT
Noise Level
*Product specifications are subject to change without further notice.
PM 1000/2000/3000 LCD Online
05: ECO voltage range setting
HLS: High loss voltage; LLS: Low loss
voltage. Range from +7V to +24V /-7V to
-24V of the nominal voltage.
06: Bypass enable/disable as UPS is
off
ENA/DIS (Default)
07: Bypass voltage range setting
HLS: Bypass high voltage point
230-264 Vac (Default: 264 Vac)
LLS: Bypass low voltage point
170-220 Vac (Default: 170 Vac)
08: Bypass frequency range setting
HLS: Bypass high frequency point;
LLS: Bypass low Frequency point
For 50Hz output frequency models
51-55Hz (Default: 53.0Hz)/
45-49Hz(Default: 47.0Hz)
For 60Hz output frequency models:
61-65Hz(Default: 63.0Hz)/
55-59Hz(Default: 57.0Hz)
Low Line Transfer
160VAC/140VAC/120VAC/110VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
Low Line Comeback
High Line Transfer
High Line Comeback
AC Mode to Batt. Mode
Inverter to Bypass
Battery Type
Numbers
Charging Current
Charging Voltage
Battery Type
Numbers
Charging Current
Charging Voltage
27.4 VDC ± 1%
Dimension, DxWxH (mm)
With battery
Net Weight (kgs)
Without battery
Dimension, DxWxH (mm)
With battery
Net Weight (kgs)
Without battery
09: Programmable outlets
enable/disable
ENA/DIS(Default)
10: Programmable outlets setting
0-999(Default: 999)
11: Autonomy limitation setting
0-999/DIS (Default) : Disable the
autonomy limitation and the backup
time will depend on battery capacity
(Default)
12: Battery total AH setting
7-999: set the external battery total
capacity from 7-999 in AH.
1K(L)
1000VA/1000W
175VAC/155VAC/135VAC/125VAC ± 5 %
≦ 2 % THD (Linear Load) ; 4 % THD (Non-linear Load)
3 hours recover to 95% capacity for internal battery@ 2A charging current
12V/7AH
3
Default 2A, max. 12A adjustable
41.0 VDC ± 1%
12V/7Ah
12V/9Ah
12V/7Ah
2
3
Default 2A, max. 12A adjustable
41.1 VDC ± 1%
54.8VDC ± 1%
397 X 145 X 220
13
6.6
410 x 438 x 88
510 x 438 x 88
11.6
14.1
6.6
7.8
20-95 % RH @ 0- 40°C (non-condensing)
Less than 50dBA @ 1 Meter (With fan speed control)
13: Charger maximum current
setting
1/2/4/6/8* in Ampere. (Default: 8A)
*Note: This setting is only available for
super charger.
14: Charger Boost voltage setting
2.25-2.40 (Default: 2.36V/cell)
15: Charger Float voltage setting
2.20-2.33
Set the charger float voltage from 2.20
V/cell to 2.33V/cell. (Default:
2.28V/cell)
16: EPO logic setting
AO: Active Open (Default). Activate
EPO function with Pin 1 and Pin 2 in
open status.
AC: Active Close. Activate EPO
function with Pin 1 and Pin 2 in close
status.
2K(L)
2000VA/2000W
300 VAC ± 5 %
290 VAC ± 5 %
40Hz ~ 70 Hz
200/208/220/230/240VAC
± 1% (Batt. Mode)
47 ~ 53 Hz or 57 ~ 63 Hz
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
3:1
Zero
< 4 ms
Pure Sinewave
12V/7AH
6
Default: 2A, Max: 8A adjustable
82.1 VDC ± 1%
12V/9Ah
4
6
Default: 2A, Max: 8A adjustable
82.1VDC ± 1%
421 X 190 X 318
23.2
9.9
630 x 438 x 88
19.5
23.3
9.4
10.6
V e r s i o n : 1 . 0
17: External output isolation
transformer connection
ENA/DIS(Default)
18: Display setting for
autonomy time
EAT (Default): Display the
remaining autonomy time.
RAT: show accumulated
autonomy time so far.
19: Acceptable input voltage
range setting
HLS: Input high voltage point
280/290/300 (Default: 300Vac)
LLS: Input low voltage point
110/120/130/140/150/160
(Default: 100Vac)
00: Exit setting
Exit the setting mode.
3K(L)
3000VA / 3000W
12V/9AH
6
82.1 VDC ± 1%
12V/9Ah
6
82.1VDC ± 1%
28
12.3
27.5
12.4

Publicité

Table des Matières
loading

Table des Matières