Phocos CIS-CU-LCD Guide De L'utilisateur page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
"3", using "+" or "-" and "OK". Press again to exit and
return to set function.
Load will be on for 1 minute. If pressing the key
Test
/
causes a load disconnect event (LVD/SOC, overcurrent)
the loads will be switched off.
Downloads local setting file. Press once, the remote
control switches to local function. Choose file name
using "+" or "-", and "OK". You can check each setting
using the corresponding key, but you cannot
Local
19, 20
modify them. You can send these settings to the
controller. For this, press "Local" again. It is now in
"SET" function. You can modify the settings and
send them to the controller.
Reads setting from the controller. When
transmitting, icon 17 "READ" is on. If the
transmission was successful, icon 2 "OK" flashes 5
Read
1, 2, 17
times. If an error occurred, icon 1 "ERROR" is
displayed. Make sure to read out only one controller at
a time.
* Single load type controller: CIS, CIS-N, CIS-MPPT, CIS-LED, CIS-N-LED,
CIS-MPPT-LED
** Dual load type controller: CIS-2L, CIS-N-2L
*** D2D: Dusk to Dawn
Display
Icon 18 "SET" on
Setting display
Icon 17 "READ" on
Reading from controller
Icon 3 "Transmit" flashes
Transmission to controller
Icon 2 "OK" flashes 5 times
Programing transmission successful
after "Transmit"
Icon 1 "Error" on after
Programing transmission failed
"Transmit"
Icon 2 "OK" flashes 5 times
Program successfully imported from
after "READ"
controller
Icon 1 "Error" on after "READ" Program import from controller failed
Low Voltage Disconnect Function
Voltage controlled (LVD): Disconnects at a fixed voltage between 11.0/22.0 V
and 11.9/23.8 V (step 0.1 V)
State of charge (SOC) controlled: Disconnects at
11.00 V/22.00 V to 11.70 V/23.40 V (SOC 1),
11.12 V/22.24 V to 11.76 V/23.52 V (SOC 2),
11.25 V/22.50 V to 11.83 V/23.63 V (SOC 3),
11.38 V/22.72 V to 11.89 V/23.78 V (SOC 4),
11.51 V/23.02 V to 11.96 V/23.92 V (SOC 5),
11.64 V/23.28 V to 12.02 V/24.04 V (SOC 6).
Load Control Function (Without Dimming)
Evening/Morning modes
Hours based on middle of night
Hours based on Dusk & Dawn
 Dusk to Dawn (D2D) mode
Standard controller mode (Morning h and Evening h OFF)
Sets morning and evening hours to activate standard controller mode.
Loads are always on if no load disconnect event (LVD/SOC, overcurrent)
happens.
Load Control Function (with Dimming)
 Evening/Morning modes
1. Hours based on middle of night
All manuals and user guides at all-guides.com
Middle of night
Middle of night
2. Hours based on Dusk & Dawn
3. Load Evening/Morning, Dimming D2D (Dusk to Dawn)
4. Load Evening/Morning, Dimming Off Mode
1)
Set both morning and evening hours to activate dimming off mode.
Loads are always on if no load disconnect event happens (LVD/SOC,
overcurrent).
Dusk to Dawn mode
1. Load D2D mode, dimming evening/morning mode
2. Load D2D mode, dimming D2D mode
3. Load D2D mode, dimming off mode
Standard controller mode (Morning h and Evening h OFF)
Set off both morning and evening hours to activate standard controller
mode. Loads are always on if no load disconnect event (LVD/SOC,
overcurrent) happens.
1. Load standard, dimming Evening/Morning mode
7
Middle of night
Middle of night
Middle of night
1)
Middle of night
Middle of night
Middle of night

Publicité

Table des Matières
loading

Table des Matières