Adjustment of Heating Operation

6 Adjustment of Heating Operation
During start-up, the heating characteristic curve is adjusted to
suit the building and local conditions. This heating characteristic
curve can be adjusted to individual temperature requirements
using the Warmer/Colder arrow buttons on the main display.
Increase the temperature with the
the last line will move to the right.
Decrease the temperature with the
the last line will move to the left.

7 DHW Heating

The desired domestic hot water temperature can be set in the
menu "Settings – Domestic hot water – Hot water set temp".

8 Menu Structure

8.1 Settings

All user settings are made in the "Settings" menu item.
The following table shows not only the menu structure and
explanations
in
the
right-hand
corresponding setting ranges. Values in bold print indicate the
factory settings.
You can access the settings menu by:
Pressing the button (MENU) for approx. 5 seconds
Confirming the settings menu item with the ENTER button.
www.dimplex.de
All manuals and user guides at all-guides.com
button. The indicator bar in
button. The indicator bar in
column,
but
also
the
Menu for setting the time.
Level for setting operating modes
Selects the operating mode
It is also possible to make changes directly using the modus
button.
Duration of party mode in hours
After the set period has elapsed, the system returns automatically
back to automatic operation again.
Duration of vacation mode in days
After the set period has elapsed, the system returns automatically
back to automatic operation again.
Settings for heating circuit 1
Sets the desired room set temperature when room temperature
regulation is selected
Sets the temperature value by which the heating characteristic
curve of heating circuit 1 is to be lowered when the temperature is
lowered
NOTE
Energy-efficient operation
For energy-efficient operation of the heat pump heating system, the
temperature level to be generated by the heat pump should be as low as
possible.
In well-insulated buildings, constant heating operation without lowering
times will normally result in lower energy costs. This is because power
peaks with high flow temperatures are avoided and the same degree of
comfort is attained at lower temperatures.
Hot water cylinder without flange heater
If the hot water set temperature exceeds the maximum attainable
domestic hot water temperature in heat pump operation, DHW
preparation is terminated once the so-called HP maximum
temperature is reached.
NOTE
Dynamic menus
The following contains a description of the complete menu. During start-
up, the regulatory functions and the menu structure are adjusted to the
specific system. Non-relevant menu items are then hidden according to
these settings.
Example: Settings for DHW preparation can only be made if the "DHW
preparation" menu item is configured with "Yes" in the preconfiguration.
Abbreviations:
HG2 = 2nd heat generator (e.g. boiler)
System-specific parameters
8.1
Setting range
International 24 h
display
Cooling
Summer
Auto
Party
Vacation
HG2
0
... 4 ...
72
0
... 15 ...
150
15.0 °C
... 20.0 °C ...
30.0 °C
0K
...
19 K