18 -Cover Replacement; 19 -Technical Features - Bpt TH 125 Mode D'emploi

Thermostat programmable thermoprogram
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TH125_ITF 24081800 01_07
All manuals and user guides at all-guides.com
15-01-2007
16:23
Fig. 57
restored following the procedure descri-
bed in chapter 4 and subsequent chap-
ters.
18 - COVER REPLACEMENT
The unit is delivered with 2 covers in diffe-
rent colours which can be used instead of
the one installed based on the room where
the unit is to be used.
To replace the batteries, proceed as follows:
18.1 - Open the cover and remove it as
shown in figure 58.
18.2 - Insert the new cover as shown in
Fig. 58
figure 59 and close it properly (fig. 60).
Pagina 19
WARNING. Clean the cover only with a soft
cloth dampened with water.
19 - TECHNICAL FEATURES
Unit for domestic and commercial use.
• Independently installed electronic device.
• LCD graphic display.
• Power supply: three penlight AAA 1.5 V
LR03 alkaline batteries.
• Autonomy: over 1 year.
• Battery low warning.
• Time available for battery replacement:
approximately 2 min.
Fig. 59
• Relay: max. voltage 250 V, max. current
5A with resistive load (2A with inductive
load).
Type of action: 1 B-U.
• Range of adjustment in heating mode:
from 6 to 24 °C.
• Range of adjustment in cooling mode:
from 18 to 31 °C.
• Three
AUTOMATIC, STAND-BY MODE.
• Selectable
COOLING.
• Manual operation enabling or system
switch-off controlled by timer, in hours or
days (up to 99).
• Room temperature measuring interval: 15 s.
operating
modes:
MANUAL,
programs:
HEATING,
19

Publicité

Table des Matières
loading

Table des Matières