Error messages on the digital display
Alarm
code
Regulation sensor error:
• Sensor not working:
Sensor signal interrupted or appears
for a short time;
• Sensor not working with unit.
E0
The message E0 appears when one
alarm is active, (temperature value is not
displayed), and flashes when other alarm
signals show or when the measurement
value of the second sensor is displayed.
Open door
dOr
Last defrost cycle ended as a result of
max. time being exceeded, and not
Ed
because of normal end of cycle
Defrost cycle completed:
• this is not an error message, but a
dF
message that the unit is in the middle of a
defrost cycle. It only appears when
parameter d6= 0.
Dirty condenser alarm:
CHt
• check parameters A4, Ac, AE and Acd.
- 36 -
Error
Assistance
Contact a sales agent.
Check multifunction jacks
and parameters A4 and A7.
Contact a sales agent
Check parameters dt, dP
and d4;
Check if defrost conducted
properly.
The message will disappear
when the next defrost cycle
finished normally.
Contact a sales agent
Contact a sales agent