A.
CERTIFICATION & INTENDED USE
A.1
Certification
1.
Model WX (Series X) & MKII (Series X) Cata-Dyne™
explosion-proof, flameless infrared catalytic gas heaters
are certified by the Canadian Standards Association (CSA)
for use in Class I, Divisions 1 and 2, Group D hazardous
locations temperature code T2C, at a maximum ambient
temperature of 40ºC (104ºF).
2.
Model WXS (Series X) is FM certified for Class I, Division I,
Group D, temperature code T2B at a maximum ambient
temperature of 40°C (104°F). Model BX (Series X) and
Model MKII (Series X) are FM certified for Class I, Division I,
Group D, temperature code T2C at a maximum ambient
temperature of 40°C (104°F).
3.
Models WX (Series X) are certified CE for use in gas
environments, Category 2, Zone 1 & 2, Group IIA.
B.

SPECIFICATIONS

To ensure the maximum efficiency of your Cata-Dyne™ heater,
it should be installed with the heating surface positioned plus
or minus 45° from the vertical plane at a height of no more than
8 ft (2.44 m). All heaters must be installed in accordance with
the latest revisions of the codes described in Table 1, page 3
and in accordance with any local codes and regulations. Before
installing the heater, all information on the heater nameplate
must be carefully reviewed. The nameplate lists all the fuel and
electrical requirements for the heater.
Table 1 – National Code Requirements
For Cata-DyneTM Heaters Installed in:
Canada
CSA/CAN-C22.1-02
NFPA 70, National
Canadian Electrical
Electrical Code
Code
NFPA 54, National Fuel
CSA/CAN-B149.1
Gas Code
Natural Gas and
Propane Installation
Code
B.1
MKII Model (Series X)
CSA and FM approved for use in Class I, Division 1 and 2, Group D
hazardous (classified) locations, T-Code T2C.
Table 2 – MKII Model (Series X)
For Both Natural and Propane Gas
Model Number
Max. Btu/hr
MKII 12x12
MKII 12x24
MKII 18x24
MKII 18x48
MKII 24x24
MKII 24x48
USA
Internationally
Install according to
local and national/
international fuel and
electrical codes
Input Ratings
Max. kW
5,000
1.464
10,000
2.929
15,000
4.393
30,000
8.786
20,000
5.857
40,000
11.715
4.
The Model BX (Series G) Cata-Dyne™ heater is certified by
CSA and FM for use in general industrial non-hazardous
locations. Models listed are certified for industrial use only,
for either natural gas or propane gas.
5.
CSA approved models are equipped for high altitudes:
0 to 4500 ft (0 m to 1370 m) above sea level. FM approved
models are equipped for high altitudes: 0 to 6000 ft (0 m
to 1829 m) above sea level.
A.2
Intended Use
The Cata-Dyne™ heater can be used in all industrial indoor
locations where a source of infrared radiant heat is required,
where adequate ventilation is available.
B.2
BX Model (Series G) *
CSA approved for use in general industrial non-hazardous
locations.
Table 3 – BX Model (Series G)
For Both Natural and Propane Gas
Model Number
Max. Btu/hr
LPG
BX 6x6
1,250
BX 6x12
2,500
BX 6x24
5,000
BX 8x8
2,222
BX 10x12
4,167
BX 12x12
5,000
BX 12x24
10,000
BX 12x36
15,000
BX 12x48
20,000
BX 12x60
25,000
BX 12x72
30,000
BX 18x24
15,000
BX 18x30
18,750
BX 18x36
22,500
BX 18x48
30,000
BX 18x60
37,500
BX 18x72
45,000
BX 24x24
20,000
BX 24x30
25,000
BX 24x36
30,000
BX 24x48
40,000
BX 24x60
50,000
*Model available for CSA only.
Input Ratings
Max. kW
NAT
LPG
NAT
1,500
0.366
0.439
3,000
0.732
0.879
6,000
1.464
1.757
2,667
0.651
0.781
5,000
1.220
1.464
6,000
1.464
1.757
12,000
2.929
3.514
18,000
4.393
5.272
24,000
5.857
7.029
30,000
7.322
8.786
36,000
8.786
10.543
18,000
4.393
5.272
22,500
5.491
6.590
27,000
6.590
7.908
36,000
8.786
10.543
45,000
10.983
13.179
54,000
13.179
15.815
24,000
5.857
7.029
30,000
7.322
7.322
36,000
8.786
10.543
48,000
11.715
14.058
60,000
14.644
17.572
3