SPECIFICATIONS
Opera ng Temperature
Environmental Protec on Ra ng
Input Voltage
Es mated ba ery run me
Weigh only
Weigh/Read
Read only
CHARGING THE BATTERY
To ensure op mum performance of the TWR- , the internal ba ery may need to be
charged for up to 16 hours before fi rst me use.
Important: If the TWR- is to be stored for an extended period, this should be in a
cool dry place with a fully charged ba ery. Always charge the ba ery indoors.
1.
Connect the power adapter at the base of the unit and plug the TWR- into a power
outlet and switch ON. The charging icon will display on the screen.
Warning: The power adaptor is intended for indoor use only. Do not expose to rain
or dampness.
2.
When the charge shows 100% the TWR- is ready to use with or without the power
adapter.
Note:
•
When the TWR- is in use, the ba ery icon will display and
show remaining charge.
•
When using the scale and the charge level falls below 10% the
ba ery icon will fl ash with a red outline. You will have about 30 minutes to complete
the weighing session before the TWR- must be charged.
•
When the charge level becomes cri cal the unit will shut down.
•
To check remaining run me at current se ngs, from the Home screen, go to
Se ngs
> About > Ba ery
•
The ba ery error icon will display if the ba ery is too hot (above +45
or too cold (below 0
but will not charge properly un l at room temperature.
2
Gallagher TWR- Weigh Scale Quick Start Guide
at 100% brightness
.
C). The Scale will keep opera ng while plugged in
o
-20
o
to 50
o
C
-5
o
to 120
o
F
IP67
12 V DC
at 60% brightness
12 hours
6 hours
3 hours
16 hours
8 hours
4 hours
o
C)