Installing The Loadbars - Gallagher TWR-5 Guide De Démarrage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
Gallagher TWR- Weigh Scale Quick Start Guide

Installing the loadbars

If using loadbars, follow these steps:
1.
Select a weighing site that provides a solid, level and well drained surface.
2.
Ensure the loadbars and pla orm are well secured and clear of any
obstruc ons.
3.
Either bolt the loadbars to the concrete pad or locate them on studs set into
the concrete. It is important that the loadbars and pla orm sit fl at without
any rocking or twis ng to avoid weighing inaccuracies.
Note: It may be necessary to shim the loadbars or pla orm to ensure there
are no twis ng pressures within the pla orm. Weights should be evenly
distributed over the top of the weigh bars.
4.
For Wired Loadbars: Connect the loadbar cables to the TWR- .
For Wireless Loadbars: The TWR-1 must be within 8-10m of the loadbars.
Refer to the Gallagher Loadbars Instruc ons for further installa on
informa on.
A beep will sound indica ng a successful connec on/disconnec on of the
loadbars.
WARNING – Do not weld the loadbars or any structure that they are
a ached to. Loadbars contain sensi ve electronic devices which will be
damaged by welding. Damage caused by welding will void warranty.
Position the TWR- :
clear of the
pla orm to ensure
it does not interfere
with the fl ow of
animals during the
weighing cycle
within easy reach of
the loadbar leads
within easy reach
of the operator (for
manual weighing)
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Twr-1

Table des Matières