Troubleshooting guide
Fault
Cause
Engine does
Automatic oil
not start
cut-out has not
responded
Spark plug
fouled
No fuel
Generator
Controller or
has too little
capacitor
or no voltage
defective
Overcurrent
circuit-breaker
has triggered
Air filter dirty
Maintenance schedule
Please adhere to the following maintenance periods
in order to ensure a failure-free operation.
IMPORTANT! The equipment must be
filled with engine oil and fuel before it
is started.
After an
After an
operating
operating
period of
period of
50 hours
100 hours
X
Remedy
Check oil level,
top up engine oil
Clean or replace
spark plug
(electrode
spacing 0.6 mm)
Refuel / have
the petrol cock
checked
Contact your
dealer
Actuate the circuit-
breaker and reduce
the consumers
Clean or replace
the filter
After an
operating
period of
300 hours
Change the
filter insert if
necessary