Please read all safety in-
formation and instructions.
Failure to observe the safety information and in-
structions can result in electric shock, fire and / or
serious injury.
Keep all safety advice and instructions in
a safe place for future reference.
Before use
Installation
You will need two open ended spanners
for install this device (spanner size 12).
Install the stand
, wheels
17
bar
as shown in figures F–I.
19
Install all parts before pouring in the fuel and
oil to avoid the fluids leaking.
To install the wheels first push the wheel axle
through the brackets on the underside of the
generator and install the wheels
in figure G.
Ensure that when installing the push bar
slanting side (fig. I / Pos. I1) is slanting outwards.
Electrical safety
Electrical cables and attached devices must be
defect free.
Never connect the generator to the mains
(power point).
Keep the cables as short as possible.
Environmental protection
Dispense of polluted maintenance and operating
materials in a suitable collection point.
All manuals and user guides at all-guides.com
Safety instructions / Before use / Operation
time, motor oil (15 W-40, approx. 0.6 l) and petrol
(unleaded normal petrol) must be put in.
and the push
15
16
as shown
15
the
start
19
kick back.
tinuously (S1) with 2600 W and short term (S2) for
a maximum of 2 minutes with 2800 W.
Earthing
Earthing is needed to disperse static discharge.
Connect a cable from one side of the earthing
connector
of the generator (fig. C / Pos. 4)
4
and from the other side to an external ground.
Operation
ATTENTION! When being used for the first
Check the fuel level and the oil, and if necessary
top them up.
Make sure you have adequate ventilation.
Ensure that the spark cable is securely in the
spark plug.
Unplug any electric device connected to the
generator.
Start the engine
ATTENTION! When starting with the express
you can injure your hand with the sudden
13
Wear protective gloves when starting.
Open the petrol tap
by turning the tap down-
14
wards.
Put the on / off switch
11
Turn the choke lever
to I
12
position).
Start the engine with the express start
sharply pulling the handle. If the engine has not
started pull the handle again.
Push the choke lever
back once the engine
12
has started (in the right position).
To load the generator
Connect the device to the 230 V∼ socket
ATTENTION! This socket can be loaded con-
to the on position.
I (in the left
by
13
.
3
GB
31