10. Keep the generator away from children.
11. Emission levels are represented in the technical
data under the stated values for sound power
level (L
) and sound pressure level (L
WA
are not compulsory definite working levels. Be-
cause there is a connection between emission
levels and immission levels, this can not reliably
used to determine the potentially necessary ad-
ditional precautions. Influencing factors on the
workforce's current immission level includes the
properties of the work area, other noise sources,
air borne sound, etc. such as e.g. the number
of machines and other neighbouring processes
and intervals, to which the user is exposed. Also
the admissible immission levels can vary from
country to country. However, this information
gives the user of the machine the opportunity to
have a better estimation of the risks and dangers.
Occasionally acoustic measurements should be
take after installation in order to determine the
sound pressure level.
Take special care when needing to use highly
volatile fuels as a starting aid.
Ensure the connected electrical devices (incl.
power cable and plug connections) are not
defective.
Some parts of the combustible engine are hot
and may cause burns. Please observe the warn-
ings on the generator.
Do not refuel during operation. Do not refuel
whilst smoking nearby or near open fire.
When operating in well ventilated spaces, ad-
ditional measures must be taken to prevent fire
and explosions.
ATTENTION: Only use unleaded normal
petrol as fuel.
) and
pA
Important! Switch off
the engine before refueling.
Important! Hot parts.
Keep your distance.
Safety instructions / Before use
Please read all safety in-
formation and instructions.
Failure to observe the safety information and in-
structions can result in electric shock, fire and / or
serious injury.
Keep all safety advice and instructions in
a safe place for future reference.
Before use
Installation
You will need two open ended spanners
for install this device (spanner size 12).
Install the stand
17
bar
as shown in figures F–I.
19
Install all parts before pouring in the fuel and
oil to avoid the fluids leaking.
To install the wheels first push the wheel axle
through the brackets on the underside of the
generator and install the wheels
in figure G.
Electrical safety
Electrical cables and attached devices must be
defect free.
Never connect the generator to the mains
(power point).
Keep the cables as short as possible.
Environmental protection
Dispense of polluted maintenance and operating
materials in a suitable collection point.
Earthing
Earthing is needed to disperse static discharge.
Connect a cable from one side of the earthing
connector
of the generator (fig. C / Pos. 4)
4
and from the other side to an external ground.
, wheels
and the push
15
as shown
15
GB
16
33