Télécharger Imprimer la page

Kozy Heat Fireplaces OCK-S51A Mode D'emploi page 3

Publicité

Les langues disponibles

Les langues disponibles

Conversion Kit Components
(1) Gas Conversion Label
(1) Valve and Pilot Assembly Conversion Instructions
(1) Gas Label
(1) Pilot Injector Propane: #30
(1) Burner Orifice Propane: #51
High Altitude Conversions
For high altitude installations in the United States, refer to the
American Gas Association guidelines for the gas designed appliances
derating method. For elevations above 2,000' (610 m), input ratings are
to be reduced by 4% for each 1,000' (305 m) above sea level.
When the appliance is installed at elevations above 4,500' (1,372 m),
the certified high altitude rating shall be reduced at the rate of 4% for
each additional 1,000' (305 m). Refer also to CSA-B149.1 Natural Gas
and Propane Installation Code, local authorities, or codes which have
jurisdiction in your area regarding the derate guidelines.
CAUTION: The gas supply shall be shut off prior to disconnecting the
electrical power, before proceeding with the conversion.
A. Prepare the Fireplace
Step 1: Turn off the burner with the installed control component (wall
switch, remote, or thermostat).
Step 2: Remove the safety barrier and access cover. Push in the gas
control knob on the gas valve and turn clockwise to OFF
position.
Step 3: Remove the glass frame assembly, perimeter media (if installed)
and burner media.
Step 4: Remove burner media tray and burner.
Refer to the installation manual for more information.
B. Replace Burner Orifice
Step 1: Remove the existing orifice cap.
Step 2: Replace with the orifice cap included with this kit. Tighten cap
securely. The sizes are stamped on the orifices.
Table 1, Burner Orifice Size at Elevations 0-4,500' (1,372 m)
Fuel
Orifice Size
Propane
Burner ori ce
FIGURE 1, Burner Orifice
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
C. Convert Pilot Assembly
Step 1: Remove and save the clip securing the pilot hood to the pilot
bracket. Remove pilot hood by pulling directly up from the
pilot bracket.
5/32
Step 2: Insert a
the injector, and turn counterclockwise to remove it from the
injector journal.
Step 3: Insert hex key into the end of the injector to install into the
injector journal. Turn clockwise to a recommended torque of 9
lb. in (1.0 Nm). (Propane injectors have groove around the top,
NG injectors do not. Numbers are stamped on pilot injectors).
Step 4: Align the base of the pilot hood with the slot in the side of the
pilot journal. Push the pilot hood directly onto the pilot jacket.
Reinstall clip securing pilot hood to pilot bracket. The hood
must sit squarely on the bracket for proper operation.
Groove
#51 (DMS)
FIGURE 2, Converted Pilot and Pilot Injectors
D. Convert Gas Control Valve
Follow the HI/LO pressure regulator instruction sheet included with
this conversion kit to convert the gas valve.
E. Complete the Conversion
Step 1: Adjust the venturi. Loosen the screw, then adjust the cap to the
correct setting. Re-tighten the screw. See TABLE 2.
Step 2: Reinstall the burner and burner media tray.
Step 3: Reinstall burner media and perimeter media (if installed).
Step 4: Turn the gas control knob counterclockwise to ON.
Step 5: Reconnect electrical power.
Step 6: Check for leaks at all connections with soapy water.
" (4mm) hex key into the hexagonal key-way of
Injectors
Propane
Natural gas
EN
3
#OCK-S51A