TEChNICAL DATA
Contol unit supply
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
Wire connections shown in Fig. 1 are described hereunder:
Terminal
Function
no.
1-2
24Vac/dc
3-4
Antenna
9-10
SCA/SRL/2° Ch
Radio
11-12
24 Vdc
13-14
Flashing light
17
PED/CLOSE
18
Step-by-Step/OPEN With "OPEN/CLOSE" logics Off: Input, step-by-step push-button (Normally Open contact).
19
PHOT C
20
PHOT
21
STOP
22
COM
23-25
Motor 1
24
Motor 1, Ground
26-28
Motor 2
27
Motor 2, Ground
BN.CB
Buffer battery
1) Cut off power supply.
2) Manually release the gate leaves, move them to around half their stroke and block them again.
3) Restore power supply.
4) Send a sep-by-step control by using the push-button connected to the Input, Step-by-Step (PP), radio control or push-button <->.
12
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1/2 motor 24Vdc
120/120 W
24Vdc 500mA max.
IP44
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64
CP.BEN CONTROL UNIT
WIRE DIAGRAM
Description
Input, power supply, 24Vac/24Vdc.
Connection to insertable radio-receiver card antenna (3-screen/4-signal).
Volt-free contact, Normally Open, controlled by logics "2° Ch Radio" (2
and "SRL".
With "2
Radio channel" logics On: active output as 2
nd
With "2
Radio channel" logics Off:
nd
-
With "SRL" logics On: Contact for courtesy light control
-
With "SRL" logics Off: Contact for "SCA" open gate light
Output, accessories power supply, 24Vc/0.5A max (12+/11-).
Connection of warning flashing light, 24Vdc 15W max.
With "OPEN/CLOSE" logics Off: Input, pedestrian push-button (Normally Open contact). It
controls motor 1 opening.
With "OPEN/CLOSE" logics On: Input, close push-button (Normally Open contact). It
controls both motors.
With "OPEN/CLOSE" logics On: Input, OPEN push-button (Normally Open contact). It
controls the opening of both motors.
Input, photocell is activated only during closure (Normally Closed contact Normally Closed
contact)
Input, photocell is activated during opening and closing (Normally Closed contact)
Input, STOP push-button (Normally Closed contact)
Common for all control inputs.
Pre-wired rapid connector, motor 1
Ground of motor 1
Extractable connector for connection of motor 2: 24Vdc 120W max
Ground of motor 2
Rapid connector for connection of battery charger card BN.CB
TO ChECK CONNECTIONS
Radio channel)
nd
Radio channel.
nd