Correct electrical installation
− Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
− A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. Working as a qualified
person also includes the recognition of possible hazards and the adherence to the pertinent regional and national
standards, rules and regulations.
− For your own safety, please consult a qualified electrician.
− The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
− Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
− Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the
identification H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− Only operate the unit if no persons are in the water!
− Keep the socket and power plug dry.
Submersed installation
Attention! Risk of damage! Ensure that the unit does not take in air or run dry.
Cut the stepped hose adapter to suit the hose diameter and screw onto the return. Place the unit horizontally with its
feet downward.

Dry installation

Attention! Risk of damage! Ensure that the unit does not take in air or run dry. Do not connect the unit to the
domestic water lines.
Cut both stepped hose adapters to suit the hose diameters, then screw each adapter onto the intake (front) and return
(top). Place the unit horizontally with its feet at the bottom. To prevent air from being taken in, ensure that unit and
supply hose are always 20 cm below the water level. For optimum operation, OASE recommends using a 1½'' hose,
max. 5 m long, on the suction side.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
This is how to connect the power supply:
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
The pump power can only be controlled by an OASE current management unit.
Attention! The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down. Risk of accident!