SICK UE3212 Notice D'instructions page 88

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB
Chapter 3
Fig. 1: Structure and status
indicators of the safe bus
node UE3212
Tab. 1: Meaning of the LED
status indicators
88
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Product description
3.3
Structure and status indicators of the safe bus node
UE3212
Labelling field
LED I1 yellow
LED I2 yellow
Socket M12 I1/2
LED ALARM red
You will find the technical data and a dimensional drawing in chapter 8, "Technical
specifications".
Display
FAULT
Red
Red
Red
PWR
Green
Green
ALARM
Red
Red
I1/I2
Yellow
Yellow
Meaning
AS6Interface communication error-free
AS6Interface communication error
Peripheral fault: voltage supply at socket I1/I2 overloaded
or short-circuited
No voltage supply
AS6Interface voltage supply o. k.
Alarm output not activated
Alarm output activated
No current on input for the related socket
Current on input for the related socket