Install the continuous-flow heater as described in the
illustrated section. Observe the instructions in the text.

Safety information

Risk of electric shock!
Switch off the mains voltage supply immediately if
a fault occurs.
We do not accept liability for damage resulting from
failure to heed these instructions.
The continuous-flow heater may only be connected
and put into operation by a qualified professional.
Never open the appliance without disconnecting the
power supply beforehand.
The statutory regulations of the respective country, as
well as those of the local electricity and water suppliers,
must be adhered to.
The continuous-flow heater is a Class
must be connected to the protective earth.
The appliance must be permanently connected to installed
pipes. The conductor cross-section must comply with
the installed appliance power.
Caution
: Earthed water pipes may give the appearance of
a connected protective earth.
To guarantee compliance to relevant safety regulations,
an all-pole separator must be fitted during installation.
The contact opening must be at least 3 mm.
The continuous-flow heater is only suitable for closed
(pressurized) operation.
The tap and outlet fittings must be appro ed for operation
with closed (pressurized) continuous-flow heater systems.
The continuous-flow heater can be operated with cold or
pre-warmed water (for example from a solar energy unit
water supply). Observe the technical data and the special
accessories for this purpose.
The continuous-flow heater is only suitable for connection
to DVGW (German Technical and Scientific Association for
Gas and Water) approved plastic pipes.
The continuous-flow heater may only be installed in a
frost-free room.
Disconnect the electrical connection cable from the
supply and shut off the water supply before connect-
ing the appliance!
Connect the water supply and then connect the elec-
trical supply.
Only make the openings which are required for instal-
lation on the rear of the appliance. If the appliance is
reinstalled, the unused openings must be provided with
watertight sealing.
Do not touch electrically live parts after installation.
6
All manuals and user guides at all-guides.com
en
Installation
I.
Unpack the appliance and check for transport-related
damage.
Please dispose of the packaging, and if applicable, the old
appliance in an environmentally-friendly manner.
II.
Important: Only use the supplied installation set.
The supplied water connection nozzles must be installed!
Shut off water supply. The electrical connection (connec-
tion cable) must be disconnected from the power supply.
Unscrew the fuse or switch off the circuit breaker.
III.
The continuous-flow heater must be mounted on the
I appliance and
wall. Attach it if necessary on the lower adjustable screws.
The distance to the wall is variable. You can compensate
for any unevenness of the wall's surface.
The grommet must tightly surround the connection cable.
If it is damaged during mounting, the openings must be
provided with watertight sealing.
IV.
The continuous-flow heater must be vented. The
warm water tap must be opened and the appliance
must be flushed out thoroughly for 1 minute with
at least 6 litres of water.
V.
The electrical supply terminal can be fitted at the top or
bottom. The sheath of the connection cable must extend
for at least 40 mm into the appliance.
Set the power using the power selector switch before
connecting the wires to the mains connection terminal:
Set DE 1821555 to 18 kW (down) or 21 kW (up).
Set DE 2427555 to 24 kW (down) or 27 kW (up).
The set power must be marked on the ratings plate.
Now screw the wires tightly into the mains connection
terminal.
Unpacking/Removing the cover
Preparations for installation
Wall mounting
Water connection
Electrical connection/Mounting