CV61
Back-EMF: Adjustment frequency
Specifies how often per second the motor voltage is
adjusted - accordingly, the loco will react to curves and
grades immediately or with a short delay
0 = immediate adjustment, 255 = maximum delay
CV62
Back-EMF: Max. Adjustment
Limits the total adjustment in motor voltage. If there is
a very large load on the motor, the adjustment will not
exceed this value - for more realistic operations, so that
locos will slow a bit on grades.
0 = no adjustment, 255 = maximum adjustment
CV67
Speed steps programmed by user (see CV29):
to
28 speed steps are programmed in CV67 to CV94.
CV94
With LGB MTS, every second value is skipped
(14 speed steps).
Factory pre-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76,
84, 92, 102, 112, 124, 136, 152, 168, 188, 208, 230, 255
Pre-set values for user-programmable speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112, 120, 128,
136, 144, 152, 160, 168, 176, 184, 192, 208, 224, 240, 255
Hint: The speed steps are factory pre-set and programm-
ing is not necessary. We recommend the 55045 MTS
PC Decoder Programming Module for programming.
CV131
F button for Sound 1 (whistle)
0 = not assigned, 1 = button 1; 2 = button 2, etc.
CV132
F button for Sound 2 (brake sound)
see CV131
CV133
F button for Sound 3 (bell)
see CV131
CV134
F button for Sound 4 (conductor announcement)
see CV131
CV135
F button for Sound 5 (air pump fast)
see CV131
CV136
F button for Sound 6 (air pump slow)
see CV131
CV137
F button for Sound 7 (injector)
see CV131
CV138
F button for Sound 8 (coal shoveling)
see CV131
CV139
F button for Sound 9 (generator)
see CV131
CV140
F button for Sound 10 (conductor whistle)
see CV131
CV141
F button for Sound 11 (crossing signal)
see CV131
CV142
F button for Sound 12 (cleaning smokebox)
see CV131
CV147
F button for sound off/on
see CV131, function value 0: Sound always is on.
(0-255)
[16]
(0-255)
[255]
(0-255)
(0-12)
[1]
(0-12)
[2]
(0-12)
[3]
(0-12)
[4]
(0-12)
[0]
(0-12)
[9]
(0-12)
[12]
(0-12)
[5]
(0-12)
[11]
(0-12)
[10]
(0-12)
[0]
(0-12)
[0]
(0-12)
[8]
23