Operating malfunctions
Removing a blockage in the dust container.
24
Figure
Unfasten the 4 snaplocks by pushing them in the direc-
tion of the arrow and remove the dust container lid.
Loosen the blockage, e.g. with a screwdriver, and tap or
vacuum it out.
(You must fit a dust bag in the vacuum cleaner
before vacuuming it out - see Figure 29)
25
Figure
Put the dust container lid back on and push in the direc-
tion of the arrow until you hear the 4 snaplocks lock into
place.
Caution: the micro- and permanent filters must be
!
cleaned following any operation malfunctions (see
Figures 22 and 23).
Using MEGAfilt
SuperTEX dust bags
®
If necessary, a MEGAfilt
SuperTEX dust bag can be used
®
instead of the dust container.
26
Figure
Open the dust bag compartment lid (see Figure 18)
Remove the dust container and fit the
MEGAfilt
SuperTEX dust bag.
®
Close the dust bag compartment lid.
The required suction power can be selected by adjusting the
suction regulator (see Figure 16).
Low
suction range:
For vacuuming delicate fabrics, e.g. curtains.
Moderate
suction range:
For daily vacuuming of lightly soiled floors.
High
suction range:
For vacuuming durable floor coverings, hard floors and
for heavily soiled surfaces.
Turbo
range:
For vacuuming stubborn dirt and very heavily soiled sur-
faces.
Replacing the MEGAfilt
SuperTEX dust bag
®
27
Figure
If the dust bag change indicator lights up brightly and
evenly when the floor tool is lifted from the carpet and
the highest suction power is selected, the dust bag must
be changed, even though it may not yet be full. In this
case it is essential to change the dust bag due to the
type of material it contains.
Open the dust bag compartment lid by moving the dust
compartment locking lever in the direction of the arrow.
14
All manuals and user guides at all-guides.com
Figure
Figure
!
Replacing the motor protection
filter/exhaust filter
Cleaning the motor protection filter
The motor protection filter should be cleaned regularly by
knocking out the dirt and rinsing.
Figure
You can obtain a replacement motor protection filter from
our aftersales service (see replacement parts p. 16).
Replacing the HEPA filter*
The HEPA filter should be replaced once a year.
Figure
Figure
* Dependent on model
28
Seal the MEGAfilt
SuperTEX dust bag by pulling the
®
locking tab and then remove the bag.
29
Insert a new MEGAfilt
SuperTEX dust bag into the hold-
®
er and close the dust bag compartment lid.
Caution: the dust bag compartment lid will only close
when the MEGAfilt
SuperTEX dust bag, textile dust
®
bag or dust container are inserted.
If the dust bag change indicator is still lit after the
dust bag has been changed, please check whether
the nozzle, tube or flexible hose are blocked.
30
Open the dust bag compartment lid (see Figure 18).
Pull out the motor protection filter in the direction of the
arrow.
Clean the motor protection filter by tapping it.
If it is very dirty, the motor protection filter should be
rinsed.
The filter must then be left to dry for at least 24 hours.
After cleaning, insert the motor protection filter into the
appliance as far as it will go and close the dust bag
compartment lid.
31*
Press the locking tab in the direction of the arrow to
unlatch the exhaust grille and open it.
Unlatch, remove and dispose of the HEPA filter by
pressing the tab in the direction of the arrow.
32*
Slide the new HEPA filter under the two retaining ribs
and push in the direction of the arrow until it engages.
Close the exhaust grille.