12XT
COAXIAL ENCLOSURE
user manual
VERSION 1.2
Activate the LOAD PRESET menu from the LA4 amplified controller front panel and then select the desired preset.
Refer to the ''LA4 - User Manual'' for additional instructions. The preset is also accessible using the LA NETWORK
MANAGER software (refer to ''LA NETWORK MANAGER - User Manual''). Accessible controls in ''FULL
RANGE'' mode for ACTIVE 12XT are shown in the following chart:
Table 5: Accessible controls in ''FULL RANGE'' mode for ACTIVE 12XT
LA4 Inputs/
Outputs
IN A
IN B
OUT 1
OUT 2
OUT 3
OUT 4
* IN: input signal.
A: channel A.
7.3.2
"HIGH-PASS" mode
In the ''HIGH-PASS'' mode the ACTIVE 12XT enclosures are 100 Hz high-pass filtered to allow for coupling with the
dedicated complimentary SB118 subwoofers. The bandwidth of the system is extended down to 32 Hz. The
recommended ratio is one ACTIVE 12XT for one SB118.
7.3.2.1
The first two ACTIVE 12XT enclosures are connected to output channels 1 and 3 of the LA4 controller. An additional
ACTIVE 12XT enclosure can be connected in parallel with each of the first ones. Therefore a single LA4 amplified
controller can drive up to four ACTIVE 12XT enclosures (Figure 10).
Note: The system resources are optimized for two or four ACTIVE 12XT per LA4.
12XT_UM_ML_1.2
All manuals and user guides at all-guides.com
Elements
Preset
to connect
assignments*
Input signal A
IN_A
Input signal B
IN_B
ACTIVE 12XT
LF_A
HF_A
ACTIVE 12XT
LF_B
HF_B
B: channel B.
LF: low frequency transducer.
Connecting ACTIVE 12XT to LA4
w w w . l - a c o u s t i c s . c o m
Accessible (O) and blocked (X) parameters
Mute
Gain
Delay
X
O
O
X
O
O
O
X
X
O
X
X
O
X
X
O
X
X
HF: high frequency transducer.
Polarity
O
O
X
X
X
X
18 en