INFORMATOIN NOISE / MEAN ACCELERATION VALUE
The tools are suppressed in accordance for the prevention and
elimination of radiodisturbances measured in accordance with
standard:
UNI EN ISO 15744 - EN ISO 28927.
Sound pressure level / Sound power level
L PA
L WA
dB(A)
RE21ACM
78
89
RE21ALN
79
90
RS21A
79
90
DANGER The indicate measurements refer to new power
tools.Daily usa causes the noise and vibration values to
change.
Displayed emission values are comparative and are to be
employed fora provisional assessment of the operator's risk
exposure during the work period.Appropriate evaluation of work
period must also include tool's idle and stopperiods. These
emission values represent the tool's main applications. If the tool
is used for other applications, with other accessories, or if it does
notundergo regular maintenance, emission values can
significantly increaseduring operations.
Use hearing protection!
DISPOSAL
The product, when it reaches the end of its life, must not be
dispersed in theenvironment or thrown away as household waste.
It must be disposed atauthorized recycling centres (contact your
local authorities to know where todispose of the product
according to the law). The correct disposal of the
productcontributes to the health and preservation of the
environment.Illegal disposal of the product will entail penalties
against the offenders.Disposing of the product correctly
contributes to protecting human health andsafeguarding the
environment. Any illegitimate disposal of the product will
bepunishable by law.

CONFORMITY DECLARATION

We declare on our responsibility that the hand-held power tool, which is
mentioned in the present operating manual, is in conformity with the
Essential Requirements of Safety of the following Directive:
2006/42/CE Macchine
3 axis vibration level
he tests have been carried out in accordance with following Standards:
Uncertainty
a h
Uncertainty
UNI EN ISO 11148-8 - UNI EN ISO 15744 - UNI EN ISO 28927
m/s
2
3
3.80
1.20
3
3.95
1.35
3
3.75
1.00
Technical file at:
RUPES S.p.A.
Via Marconi, 3A
20080 VERMEZZO (Mi) - Italy
Vermezzo (MI), 03/02/2014
15/05/2017
11.50
Pagina 11
S.p.A
IL PRESIDENTE
G. Valentini
11