Télécharger Imprimer la page

SICK CoreTech DRS60 Notice D'instruction page 8

Publicité

Les langues disponibles

Les langues disponibles

CoreTech Encoder
Encoders with servo flange
In this flange design, there are 2 installation
options:
• Via the 3 threaded holes on the flange
side or
• With servo clamps on the servo
groove
Subject to change without notice
Installation via threaded holes on the
flange side (Figure 1)
Lock the drive shaft on the application side.
Mount the coupling (1) on the encoder; take
care that this does not touch the encoder
flange. Push the encoder, with mounted
coupling (1), onto drive shaft and mounting
spigot into the centring recess. (2)
Fix the encoder with 3 M4 screws (3).
Fix the coupling (1) to the drive shaft. The
coupling must not be subjected to any axial
stresses.
Make the electrical connections with the
voltage switched off. Switch on the voltage
and check the functioning of the encoder.
Installation with servo clamps
(Figure 2)
Lock the drive shaft on the application side.
Mount the coupling (1) on the encoder; take
care that it does not touch the encoder
flange. Mount the servo clamps (4) with M4
screws (5).
Do not tighten screws, rotate the servo
clamps so that the encoder flange can be
pushed into the centring recess.
Push the encoder, with mounted coupling (1),
onto drive shaft and centring recess.
Push the servo clamps (4) into the groove
by rotating them and tighten slightly. Fix the
coupling (1) to the drive shaft. The coupling
must not be subjected to any axial stresses.
Tighten all 3 screws on the servo clamps.
Make the electrical connections with the
voltage switched off. Switch on the voltage
and check the functioning of the encoder.