VII. INSTALLING THE CEILING ASSEMBLY (8000 SERIES)
The optional Elect-A-Heat is intended to take the chill out of
the indoor air when the air is a few degrees too cool for
comfort. The Elect-A-Heat is an effective "chill chaser". It
is not a substitute for a furnace.
Make sure that you have properly matched the roof top heat
pump and interior ceiling assembly. The following step by
step instructions must be performed in the following sequence
to insure proper installation.
A.
Carefully uncarton the ceiling assembly. Controls
are factory installed in the ceiling assembly (except
ceiling assemblies for applications with remote
control box/thermostat).
B.
Remove the shroud from the ceiling assembly plate.
C.
THIS ENTIRE STEP "C" IS NOT REQUIRED ON
"COOLING ONLY" CEILING ASSEMBLIES. On
ceiling assemblies equipped with the Elect-A-
Heat heater package (heat/cool ceiling assemblies),
detach the bottom heating element support plate by
removing the screws located around the outer edge.
The electrical connection plug will need to be
disconnected before the heat element support plate
can be removed.
D.
Before the ceiling assembly can be mounted to the
mount frame, the duct collar must be fastened to the
basepan of the heat pump with three (3) screws
(See Figure 6).
E.
Secure the ceiling assembly plate to the mounting
frame with the screws provided.
F.
Pull fabric duct material through ceiling assembly
discharge duct opening. Slit the 4 corners of fabric
duct which extends below duct opening (See
Figure 6).
DANGER
- FIRE HAZARD -
DO NOT USE FABRIC DUCT TAPE ON OR AROUND
All manuals and user guides at all-guides.com
NOTE
FABRIC DISCHARGE AIR DUCT COLLAR.
ALUMINUM TAPE MAY BE USED IF NEEDED.