FIGURE 7
FIG
URE
8
VIII. COMPLETING THE INSTALLATION (8000 SERIES)
To complete the installation and system checkout
requirements, the following steps must be performed.
A.
Check the thermostat probe position. Make sure the
thermostat probe is routed through the holding guide
and is not touching any metal surface.
B.
THIS ENTIRE STEP "B" IS NOT REQUIRED ON
"COOLING ONLY" CEILING ASSEMBLIES.
Reinstall the Elect-A-Heat assembly by first;
connecting the heat plug from the selector switch
control box to the heater receptacle in the Elect-A-
Heat heater package, and secondly; secure the
Elect-A-Heat package to the ceiling assembly with
the screws previously removed.
C.
Make sure the non-allergenic filters are properly
positioned in the ceiling shroud.
The Following Two Sections Pertain Only To 9000 Series Ceiling Assemblies
IX. INSTALLING THE CEILING ASSEMBLY (9000 SERIES)
The optional Elect-A-Heat is intended to take the chill out of
the indoor air when the air is a few degrees too cool for
comfort. The Elect-A-Heat is an effective "chill chaser". It
is not a substitute for a furnace.
Make sure that you have properly matched the roof top heat
pump and interior ceiling assembly. The following step by
step instructions must be performed in the following sequence
to insure proper installation.
All manuals and user guides at all-guides.com
NOTE
FIGURE 9
D.
Reinstall the ceiling shroud (secure with two screws
provided by RV Products). Put the control knobs
(found in single parts package) on the selector
switch and thermostat controls.
E.
Turn selector switch to OFF position.
F.
Turn ON the power supply to the roof top heat
pump.
G.
System Checkout - RV Products manufactures a
wide
range of roof top heat pumps which incorporate
different product operation features. To properly
evaluate the performance of a newly installed heat
pump, it is necessary to review the specific unit
operation characteristics (features) described in
product operation and maintenance instructions
(Customer Envelope Package).
A.
Carefully uncarton the ceiling assembly. Controls
are factory installed in the ceiling assembly (except
ceiling assemblies for applications with remote
control box/thermostat).
B.
Remove the grille and filters from the ceiling
assembly.
11