Maintenance and Cleaning Instructions

IMPORTANT: The dryer has an air filter to prevent lint and debris build up that can damage the motor and
heating element. Routine replacement or cleaning of the air filter is needed to maintain the dryer in good
operating condition. With light to moderate wash room traffic, replacing or cleaning the air filter once a year is
recommended. If the wash room traffic is high, the air filter should be replaced or cleaned every 6 months. Read
complete instruction before proceeding.
To replace or clean the air filter:
1. Disconnect the power source.
2. Use the security hex key supplied to turn the cover mounting screws clockwise to remove the cover from the dryer.
3. Removing and replacing the air filter is easily done by gently stretching and lifting the air filter around the motor inlet
cover.
4. To clean the air filter, remove from motor inlet cover. Use soft-medium bristle ½" paint brush to clean lint, dust and
debris from the filter. If air filter cannot be completely cleared of debris, replace the filter.
5. After replacing the air filter onto the motor inlet cover, reassemble the dryer cover using the security hex key supplied to
turn the cover mounting screws counter-clockwise and tight until snug. Do not over tighten.

Troubleshooting Chart

Dryer fails to start.
Dryer will not shut off or
runs 30 seconds, then will
not re-start.
Dryer air output is slow.
Dryer air is not warm.
Warranty
Product warranties may be found under "Products" on our website at www.bradleycorp.com.
A) No power to unit.
B) Defective motor.
C) Defective IR sensor.
D) Defective dryer controls.
A) Sensor is dirty, defective or
there is a reflection.
B) Defective dryer controls.
A) Motor setting is incorrect.
A) Heater is in the "OFF" position.
B) Defective heating element.
C) Defective dryer controls.
WWW.RESTROOMDIRECT.COM
Check power to unit and connections.
Replace motor.
Replace IR sensor assembly.
Replace dryer controls.
1. Check infra-red eye for dirt or damage. Use
plastic lens cleaning solution and a soft cloth. Dry
lens with a soft cloth.
2. Make sure that sensor is not getting a reflection
from another object.
3. After electricity has been applied to the dryer, it
should turn on within few seconds. Test by placing
hands 2 - 5 inches (51 - 127 mm) below the nozzle.
Replace dryer controls.
Adjust motor setting. See pg.3 of instructions.
Adjust heater to "ON" position. See page 3 of
instructions.
Replace heating element assembly.
Replace dryer controls.