Bradley Aerix+ 2922-287300 Mode D'emploi page 4

Seche-mains
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
1. Disconnect the power source.
2. Using Table 2 to determine the recommended mounting height, select a mounting location for the hand dryer where
no reflective surfaces or objects (such as a hand basin) are directly under the infra-red sensor eye. The infra-red
sensor eye is visible from the bottom of the dryer and is located just inside the dryer's nozzle area. The minimum
mounting distance from bottom of the dryer to a reflective surface is 18 in (46 cm). When two or more dryers are
installed, they should be spaced apart 24 in (61 cm)
3. Use the security hex key supplied to turn the cover mounting screws clockwise to remove the cover from the dryer.
4. Place the hand dryer base on the wall at selected location and using the base as a template, mark locations for the 4
mounting bolt holes on the wall.
5. Fasten the base to the wall, using the type of bolts recommended in Table 3
6. Each dryer must have is own dedicated circuit.
7. Connect the dryer to the nearest suitable distribution panel.
8. Replace cover, turn screws counter-clockwise making certain not to over-tighten.
IMPORTANT:
Consult local and general regulations before performing dryer installation. Ensure the electrical
network is not overloaded. Always connect to a dedicated branch circuit with circuit breaker or fuse protection and
an electrical rating greater than the model hand dryer's rated amperage shown in Table 1 - Electrical Specifications in
accordance with the NEC (National Electrical Code) and/or CEC (Canadian Electrical Code).
Table 2
Recommended Mounting Heights from Floor to Dryer Bottom Edge
Men's washrooms
Women's washrooms
Children's washrooms, ages 4-7
Children's washrooms, ages 7-10
Children's washrooms, ages 10-13
Children's washrooms, ages 13-17
Handicap Mounting Height
Table 3
Type of Wall
Hollow Tile, Lath, Wall Board or Metal
Cement, Brick, or Tile Covered Cement or Brick
Stud Wall with wood Backing
07/12/17
Type of Bolt
1/4" (M6) screw Type or Wing Type
toggle Bolts
1/4" (M6) Stud Type Expansion Bolts
No 16 (M8) Wood Screws
4
WWW.RESTROOMDIRECT.COM
in. (cm.)
46 (117)
44 (112)
32 (81)
36 (91)
40 (102)
44 (112)
37 (94)
Minimum Bolt Length
Dependent on wall
thickness
3" (76mm)
23/4" (70mm)
Bradley P20-200 Rev. B; ECN 17-15-021
704 • 937• 2673
129 Oakpark Dr., Unit A, Mooresville, NC 28115

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aerix+ 2922-287400

Table des Matières