Installing The Stove; Assembly Sequence; Oec Installation - Olsberg Merapi Instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installing the stove

The floor on which the stove is installed must be even
and horizontal. The stove may only be installed on an
adequate load-bearing floor. The stove can be stood
on a metal floor sheet or glass sheet to protect the
flooring.
If the flooring or carpet is inflammable, a stable, heat
proof spark protection plate must be used. This must
extend 50 cm to the front and 30 cm to each side be-
yond the edge of the combustion chamber opening.
Under the stove no spark protection plate is required.

Assembly sequence

● The Ø 150 stovepipe connection can be installed at
the top or rear. The stove is supplied ready for con-
nection from above. If you wish to connect it at the
rear, the following steps must be carried out to make
the necessary modifications:
- Break out the cover in the back panel.
- Replace the connector sleeve and the sealing
cover.
● If intended, install the OEC (see chapter "OEC
installation").
● If no OEC is to be installed, carefully remove the
foam sheet between the lower front shield and the
bottom plate.
● Decide where the stove is to be installed. There
must be no objects made of combustible materials
within a distance of 80 cm of the stove's radiation
area, measured from the combustion chamber's in-
spection glass, nor may any be placed within this
area subsequently.
Minimum distance from combustible or load-
bearing walls: lateral 20 cm and rear 20 cm
● Install the pipe lining (provided on site) in the chim-
ney. The connection height can be individually spec-
ified for a top stovepipe connection, however should
not exceed 1.5 m from the connector sleeve. For the
rear stovepipe connection heights please refer the
"Technical Data" chapter. No combustible material is
permitted within a radius of 20 cm around the stove
pipe.
● Connect the stovepipe at both connection points
with stove putty so that the stove pipe is permanent-
ly sealed.
● Push the stove onto its planned position and orient it
so that the stovepipe fits into the pipe lining.
The stovepipe connections must be tight. The
stovepipe must not protrude into the chimney.
Bear in mind that on partition walls in accordance
with test specification EN 13240 the temperature
of 85°C can be reached, and with light wallpaper
or similar combustible construction materials this
can result in colour changes.
14

OEC installation

The OEC is installed as follows, which is different from
the way described in the OEC instruction manual:
● Combustion chamber door open.
● Carefully pull the lower front shield (Pos.8, Fig.3) to
the front.
● Tighten the motor retaining clip (6) with the spac-
er sleeve to the motor console. Push the servo-mo-
tor (5) onto the rotation axis of the air regulator lever
and snap into the motor retaining clip (Fig.1).
Fig.1
7
5 Servo-motor
6 Motor retaining clip
7 Door contact switch fastening position
6
5

Publicité