3.10 Menu FREQ
To set the sampling frequency, follow these steps.
Procedure
• Press [ + ] or [ - ] displays the FREQ menu,
• Press [ SEL ] displays the selected value, use [ + ] or [ - ] to scroll through the available
frequency values (32k, 44k1, 48k et 96k).
• Press [ SEL ] to store the new parameter, and to return to the previous menu
• Or press [ ESC ] to return to the previous menu without updating the parameter.
• To turn off the display, press [ ESC ].
3.11 Menu AES
This menu is used to insert channel status information in AES outputs. Consumer or professional
mode can be selected. In consumer mode sample rate, and in professional mode lock sample
rate, word length, origin and destination parameters follow the user selection.
Procedure
• Press [ + ] or [ - ] displays the AES menu,
• Press [ SEL ] displays selected channel, use[ + ] or [ - ] to scroll through the available
Channels. (ASD-712i only)
• Press [ SEL ]validates the channel and displays the mode, use [ + ] or [ - ] to select the mode
PRO (PROfessional) or CONS (CONSumer)
• Press [ SEL ] to store the new parameter, and to return to the previous menu
• Or press [ ESC ] to return to the previous menu without updating the parameter.
• To turn off the display, press [ ESC ].