LED indicators
OFF
Green, flashing
Green, continuous light
Green OFF/ON
PWR LED
OFF - briefly red - ON
Orange, continuous light Service mode
Red, flashing
Red, continuous light
Off
Green, flashing
NET LED
Green, continuous light
Red, flashing
Red, continuous light
3
Part number code
Please refer to the part number code for your device model.
Decommissioning, maintenance
CAUTION!
 Do not open the device yourself under any circumstances! There is
otherwise a risk of uncontrolled emission of laser radiation from the
device. The housing of the BCL 3xxi does not contain any parts that
need to be adjusted or serviced by the user. If faults cannot be
cleared, the device should be switched off and protected against
accidental use.
 Package the device for transport and storage in such a way that is
protected against shock and humidity. Optimum protection is
achieved when using the original packaging. Ensure compliance with
the approved environmental conditions listed in the specifications.
 Do not use aggressive cleaning agents such as thinner or acetone
for cleaning the device.
No operating voltage
Initialization phase
Device ok
Good Read
No read
Warning
Device error
No operating voltage
Bus/interface initialization
Bus operation ok
Communication error
Network error