Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking
water!
• This mixer cannot be used in conjunction with
hydraulically, electronically or thermally controlled
instantaneous heaters.
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 10)
After the installation, the output temperature of the
thermostat must be checked. A correction is necessary if
the temperature measured at the output differs from the
temperature set on the thermostat.
Safety Function (see page 10)
The desired maximum temperature for example max.
42º C can be pre-set thanks to the safety function.
Maintenance (see page 12)
• The mixer is equipped with check valves. The check
valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
6
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
English
• To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Dimensions (see page 14)
Flow diagram (see page 14)
free flow
Spare parts (see page 15)
+
Special accessories (see page 15)
order as an extra
Cleaning (see page 16)
Operation (see page 13)
Test certificate (see page 16)