OFF
Hold-to-run
hold-to-run
OFF
Photocells on opening
photc. open
OFF
Rapid closing
fast cls
OFF
Photocell test
test phot
OFF
Electric edge test
test BAR
OFF
Master/Slave
ASTER
OFF
Fixed code
fixed code
Radio transmitter
ON
radio prog
programming
OFF
1 Active Motor
1
ot. on
Gate-open or 2nd radio
OFF
sca-2ch
channel warning light
OFF
Reversing motion
change
ot.
Closing limit switch
press. svc
OFF
(special dip 1*)
pressure
traffic light
Traffic light
ON
preflashing
pre-flashing
(special dip 2*)
traffic light
r e d
l a
p
ON
Steadily lit red light
alvays on
(special dip 3*)
*=Refer for universal handheld programmer.
18
INSTALLATION MANUAL
Hold-to-run operation: the manoeuvre continues as long as the command key is kept pressed.
ON
It is not possible to use the radio transmitter.
Impulse operation: one impulse opens the gate if closed, and closes it if open.
OFF
In case of obscuring, this excludes photocell operation on opening. During the closing phase, it
ON
immediately reverses the motion.
In case of obscuring, the photocells are active both on opening and on closing. When a pho-
OFF
tocell is obscured on closing, it reverses the motion only after the photocell is disengaged.
Closes 3s after the photocells are cleared before waiting for the set TCA to elapse.
ON
Command not entered.
OFF
ON
Activates photocell check (Fig. H)
OFF
Deactivates photocell check
Activates electric edge check (Fig. H)
ON
OFF
Deactivates electric edge check
ON
The control panel is set as Master in a centralised connection.
OFF
The control panel is set as Slave in a centralised connection.
The receiver is configured for operation in fixed-code mode, see paragraph on "Radio Trans-
ON
mitter Cloning".
The receiver is configured for operation in rolling-code mode, see paragraph on "Radio
OFF
Transmitter Cloning".
This enables transmitter storage via radio:
1 – First press the hidden key and then the normal key (T1, T2, T3 or T4) of a transmitter already
memorised in standard mode by means of the radio menu.
2 – Within 10s press the hidden key and the normal key (T1, T2, T3 or T4) of a transmitter to
be memorised.
ON
The receiver exits the programming mode after 10s, other new transmitters can be entered
before the end of this time.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
This disables transmitter storage via radio.
OFF
The transmitters can only be memorised using the appropriate Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays..
ON
Only motor 2 activated (1 leaf ).
OFF
Both motors are activated (2 leaves).
The output between terminals 21 and 22 is configured as Gate-open warning light, in this case
ON
the 2nd radio channel controls pedestrian opening.
OFF
The output between terminals 21 and 22 is configured as 2nd radio channel.
Reverses the motion of motors with respect to standard operating mode: the rod comes out
ON
during opening; the rod returns during closing.
IMPORTANT: Default has no effect on the logic.
OFF
Standard operating mode: the rod returns during opening; the rod comes out during closing.
To be used when a closing backstop is present.
This function activates leaf pressure on the backstop, without this being considered as an
obstacle by the ampere-stop sensor.
ON
Therefore the rod continues its stroke for another 0.5s, after intercepting the closing limit
switch or as far as the backstop. This way, by slightly anticipating closing limit switch activa-
tion, the leaves will come to a perfect halt against the end stop plates (Fig. I Rif. A).
Movement is exclusively stopped by closing limit switch activation, in this case you must
OFF
proceed to a precise setting of closing limit switch activation (Fig. I Rif. B).
ON
Flashing is switched on when movement starts (duration 3s).
OFF
Flashing is switched off when movement starts.
ON
Red lights switched on when gate closed.
OFF
Lights switched off if gate closed.