(do not tighten them).
4. Screw the diesel hot air generator (A) to the
front handle bar (2) and the base frame (I).
Use the short screws (K), the long screws (L)
and the nuts (M).
5. Screw the rear handle bar (6) to the base
frame with the remaining long screws (L) and
nuts (M).
6. Remove the wheels again.
7. Screw the rear handle bar (6) to the base
frame with the remaining short screws (K)
and nuts (M).
8. Now fully tighten the wheels.
6.2 Fuelling
Note:
Store the required EL heating oil or diesel
fuel in a suitable fuel canister which is clearly
labeled with the words "EL Heating Oil" or
"Diesel".
Follow the regulations in force in your country
for the storage of EL heating oil and diesel.
Do not use "bio diesel" under any circumstan-
ces.
At temperatures below 5°C we recommend
the use of winter diesel in order to avoid prob-
lems with fuel intake.
EL heating oil and diesel are subject to
ageing. Supplies should be used within 6
months.
Refuel only outdoors and with equipment
which has cooled down.
Follow the safety information (section 1).
1. Remove the tank lid (Fig. 1 / Item 17).
2. Slowly fi ll EL heating oil or diesel into the tank
until the tank indicator (Fig. 1 / Item 18) indi-
cates "F". (For maximum tank capacity see
Technical Data.)
3. Refi t the tank lid.
7. Using the equipment
7.1 Switching on (Fig. 3)
Notes:
The hot air generator can be connected to
any shock-proof socket with 230 V AC and
a 10 A circuit-breaker. We recommend that
you connect the machine only to a power
supply which is protected by means of an
earth-leakage circuit breaker (RCD) with a
maximum trip current of 30 mA.
Please only use power cables that are not
Anl_DHG_360_SPK7.indb 25
Anl_DHG_360_SPK7.indb 25
GB
damaged. There is a limit to how long power
cables can be (max. 50m). The power cable
must have a cross-section of 3 x 1.5 mm².
We recommend that you go outdoors to start
up the equipment for the first time (this will
take approx. 10 minutes) so that any oil resi-
dues remaining on the sheet metal parts after
production can be burnt off.
1. Connect the power plug to an extension
cable.
2. Use the thermostat knob (Item 14) to set the
desired temperature (range + 5 °C to + 45
°C).
3. Set the ON/OFF switch (Item 13) to position
ON (I) – the equipment will start, the LED
(Item 15) will light up and the room tempera-
ture will be indicated (Item 5).
Notes:
The temperature indicator works only in the
range from -17 °C to + 37 °C. At temperatures
below -17°C the indicator will show "LO", at
temperatures above + 37 °C it will show "HI".
If the firing does not switch on, the thermostat
must be adjusted to a higher temperature. If,
contrary to expectations, the heating still fails
to switch on, switch off the equipment and
check it against the error list (section 11)
7.2 Switching off
1. Set the ON/OFF switch (Fig. 3/Item 13) to the
OFF (0) position – the equipment will switch
off .
2. Pull out the power plug.
7.3 Switching on again
1. Wait at least 10 seconds before switching on
again.
2. Switch on the equipment again as described
in 7.1 and follow all the previous notes.
7.4 What to do in an emergency
Immediately switch the ON/OFF switch to the
"0" position and unplug the equipment from
the mains power.
Get people away from the danger zone.