Insert the new bulb into the protective tube and insert the tube back into the device and
rotate by 90° to secure.
-
Replace the protective housing and tighten all screws.
-
Replace the protection grill and clip back into place (see detailed instruction in "Cleaning
the UV-C lamp")
Safety switches
-
The UV-C light will only be activated when the vacuum cleaner is in full contact with the
surface being cleaned.
-
On the bottom of the base unit there is a pressure sensitive wheel (Fig.9) that is activated
when placed in contact with a surface that needs to be cleaned.
-
There are also another 3 sensors that must also be activated for the UV-C lamp to work (Fig.
9).
-
Do not manually override the pressure sensitive wheel or cover the sensors.