Vega PULS C 22 Mise En Service page 54

Masquer les pouces Voir aussi pour PULS C 22:
Table des Matières

Publicité

13 Annexe
Command
aXRSR!
aXWSR<value1>!
aXRAPUR!
aXRPS!
aXRAPAM!
aXWAPPUL<value1>!
aXWAPPL<value1>!
aXWAPEC<value1>!
Read Power Operation Mode
Command
Response
aXRPOM!
a<value1><value2> <CR><lf>
Example:
Command
Response
0XRPOM!
0+0<CR><LF>
Write Power Operation Mode
Command
Response
aXWPOM <va-
a<value1><value2> <CR><LF>
lue1>!
Read distance unit
Command
Response
aXRDU!
a<value1><CR><LF>
54
Response
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><value2><value3><va-
lue4><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
Description
Read stage reference
Write stage reference
Read access protection unlock result
Read parametrization state
Read access protection active mode
Write access protection parametrization lock
Write access protection parametrization unlock
Write access protection unlock with emergency
code
Description
a: sensor address
<value1>: power operation mode, +0 = low power mode,
+1 = normal power mode
<CR><LF>
Description
Description
a: sensor address
<value1>: power operation mode, +0 = low power mode,
+1 = normal power model
<value2>: VVO-Status eee
<CR><LF>
Description
a: sensor address
<value1>: distance unit +0 = unit in [m], +1 = unit in [ft],
+2 = unit in [mm], +3 = unit in [in]
<CR><LF>
VEGAPULS C 22 • SDI-12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sdi-12

Table des Matières