Digital input
Supported operating mode
Standard
Sampling frequency (Fs)
Word length
Sample Rate Converter (SRC)
Sampling frequency
Word length
Dynamic range
Distortion THD+N
Bandpass ripple
Automatic fallback option
Switchover conditions
Constant delay
Constant level
Revert to initial input
Input gain
Range
Steps
Latency
Analog and AES/EBU
In standard operating mode
In low latency operating mode
LA8 product information version 7.1
AES/EBU (AES3) or electrical S/PDIF (IEC 60958 Type II)
44.1, 48, 64, 88.2, 96, 128, 176.4, or 192 kHz
16, 18, 20, or 24 bits
96 kHz (SRC referenced to the amplied controller internal clock)
24 bits
140 dB
< -120 dBFS (dB Full Scale)
± 0.05 dB (20 Hz - 40 kHz, 96 kHz)
no clock, loss of lock, CRC error, bipolar encoding error, or data slip
independent from input Fs
upon manual user selection AES/EBU gain, independent from input Fs
upon manual user selection
-12 dB to +12 dB
0.1 dB
3.84 ms (independent from input Fs)
1.18 ms (independent from input Fs)
Specications
9