Télécharger Imprimer la page

L-Acoustics LA8 Mode D'emploi page 8

Masquer les pouces Voir aussi pour LA8:

Publicité

Les langues disponibles

Les langues disponibles

Specications
Protection
Circuits protection
Transducers protection
Fans
Fans noise (free eld, 1 m)
Interface and connections
Indicators
Interface
Output connectors
L-NET connectors
Input signal distribution
Connectors
Input
Link
USB
powerCON, etherCON, speakON, Neutrik are registered trademarks of Neutrik AG.
CA-COM is a trademark of ITT Cannon.
Analog input
Input impedance
Maximum input level
A/D conversion
8
heat sinks and transformers temperature monitoring
inrush-current limitation
main supply failure and over-voltage detection
output DC protection
output over-current protection
L-DRIVE:
excursion
temperature
over-voltage
2 fans, temperature-controlled speed
at minimum speed: 24 dBA
at maximum speed: 42 dBA
1 LED for L-NET information
For each output: 7 LEDs for mute, load, signal, levels and limit/clip
information
2 × 20 characters LCD screen
2 × 4-point speakON
1 × 8-point CA-COM
2 fast Ethernet RJ45 (in/out)
®
2 Neutrik
female XLR3, IEC 268, ESD protected (analog)
®
2 Neutrik
male XLR3, IEC 268, ESD protected (analog)
1 Mini-B type female USB (not used)
22 kΩ (balanced)
22 dBu (balanced, THD 1%)
two cascaded 24-bit analog/digital converters (130 dB dynamic range)
LA8 product information version 7.1

Publicité