[EN] Safety
Safety instructions
1.
Read this manual
2.
Follow all SAFETY INSTRUCTIONS as well as DANGER and OBLIGATION warnings
3.
Never incorporate equipment or accessories not approved by L-Acoustics
4.
Read all the related PRODUCT INFORMATION documents before exploiting the system
The product information document is included in the shipping carton of the related system component.
5.
Environments
Use the product only in E1, E2, E3, or E4 environments according to EN55103-2 standard.
6.
Radio interference
A sample of this product has been tested and complies with the limits for the EMC (Electro Magnetic Compatibility)
directive. These limits are designed to provide reasonable protection against harmful interference from electrical
equipment. However, there is no guarantee that interference will not occur in a particular installation.
7.
Power cord caution
Do not use the product if the power cord is broken or frayed.
Protect the power cord from being walked upon or pinched - particularly at the plugs and the point where the
power cord exits from the apparatus.
8.
Mains supply
Only connect the LA8 (CE model) or LA8US (US model) to an AC power outlet rated 230 V, 16 A, 50-60 Hz or
120 V, 30 A, 50-60 Hz.
Only connect the LA8JP (Japan model) to an AC power outlet rated 100 V, 30 A, 50 - 60 Hz or 200 V, 15 A,
50-60 Hz.
9.
Three-phase circuit
Verify that each phase works, in particular the neutral one.
Balance the loads between the three phases.
Never try to reproduce a 230 V circuit connecting an LA8 or an LA8US to two live wires of a 120 V three-phase
circuit.
Never try to reproduce a 200 V circuit connecting an LA8JP to two live wires of a 100 V three-phase circuit.
10. Electrical generator
You must power on the generator before powering on the amplied controllers
Verify that the amplied controllers are turned off before powering on the generator.
11. Thermal circuit breaker
Always interconnect a thermal circuit breaker between the product and the mains.
The circuit breaker current rating depends on the mains voltage rating as follows:
16 A for 230 V or 30 A for 120 V (LA8 or LA8US), 15 A for 200 V or 30 A for 100 V (LA8JP).