Danfoss VLT HVAC FC 101 Guide Rapide page 28

Masquer les pouces Voir aussi pour VLT HVAC FC 101:
Table des Matières

Publicité

Programmation
4
4
Illustration 4.4 Assistant de configuration pour les applications en boucle ouverte
Les par. 1-46 Position Detection Gain et 1-70 PM Start Mode sont disponibles dans la version 2.80 ou supérieure du logiciel.
26
VLT®HVAC Basic Drive FC 101
At power up the user is
asked to choose the
prefered language.
Select language
[1] English
Setup 1
Motor current
Status
Quick
Main
Menu
3.8
Menu
Menu
Com.
Motor nominal speed
3000
OK
On
Motor Cont. Rated Torque
Warn.
5.4
Alarm
Stator resistance
0.65
O
Auto
Hand
Reset
On
On
Motor poles
8
Power Up Screen
Back EMF at 1000 rpm
57
OK
The next screen will be
the Wizard screen.
Press OK to start Wizard
Press Back to skip it
Setup 1
Main
Status
Quick
if
OK
Menu
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Auto
Hand
Reset
On
On
Wizard Screen
if
0.0 Hz
0.0 kW
Setup 1
Status
Quick
Main
Menu
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Auto
Hand
Reset
On
On
Status Screen
The Wizard can always be
reentered via the Quick Menu!
(Do not AMA)
Wizard completed
Auto Motor Adapt OK
Press OK to accept
Press OK
0.0 Hz
0.0 kW
Danfoss A/S © 08/2014 Tous droits réservés.
... the Wizard starts
Select Regional Settings
[0]
Power kW/50 Hz
Grid Type
[0]
200-240V/50Hz/Delta
Motor Type
PM motor
Asynchronous
[0]
A
RPM
Nm
Ohms
Motor Type = IPM
q-axis Inductance (Lq)
V
5
mH
Motor Type = SPM
IPM Type = non-Sat.
PM Start Mode
[0]
Rotor Detection
Position Detection Gain
100
%
Locked Rotor Detection
[0]
O
Locked Rotor Detection Time[s]
0.10
s
Max Output Frequency
65
Hz
Motor Cable Length
50
m
Set Motor Speed low Limit
0000
Hz
Set Motor Speed high Limit
0050
Hz
Set Ramp 1 ramp-up time
0010
s
Set Ramp 1 ramp-down Time
0010
s
Motor Type = PM Motor
Select T53 Mode
Current
[0]
Current
Set T53 Low Current
04.66
A
Set T53 High Current
13.30
A
Set Min Reference
0000
Hz
Set Max Reference
0050
Hz
Select Function of Relay 1
[0]
[0] No function
Select Function of Relay 2
[0]
No function
Automatic Motor Adaption
[0]
O
Do AMA
AMA running
-----
AMA OK
Asynchronous Motor
Motor Power
1.10
kW
Motor Voltage
400
V
Motor Frequency
50
Hz
Motor Current
4.66
A
Motor nominal speed
1420
RPM
IPM Type = Sat.
d-axis Inductance Sat. (LdSat)
5
mH
q-axis Inductance Sat. (LqSat)
5
mH
Current at Min Inductance for d-axis
100
%
Current at Min Inductance for q-axis
100
%
Motor Type = Asynchronous
Active Flying start?
[0]
Disable
Voltage
Set T53 low Voltage
0050
V
Set T53 high Voltage
0220
V
AMA Failed
AMA Failed
MG18A604