STEAMAX MOTIV POD – PROTECTION FEATURES
15-Second Protection
When the fire button is pressed for more than 15 seconds, the device automatically turns off after 10 LED flashes.
Short Circuit Protection
1. If a short circuit occurs before operation, the LED flashes 5 times and the unit switches off automatically.
2. If a short circuit occurs during operation, the LED flashes 3 times. Please perform a reset.
Low Battery
If the battery voltage falls below 3.3 volts, the LED flashes 40 times and the unit turns off. Please recharge the battery.
Check Resistance
If the output resistance is more than 5.0 Ohm, the LED flashes slowly as soon as you press the fire button. If the output resistance
is less than 0.3 Ohm, the LED flashes 5 times in rapid succession to warn you of a short circuit.
44
www.steamax.com